[Pr. PC26_Function selection C-8 (**COP8)]

Initial value
00000050h
[Pr. PC26.0_A/B/Z-phase input encoder connection selection]
Initial value
0h
0: Disabled (only serial encoders are supported)
2: Enabled (only A/B/Z-phase input encoders are supported)

[Pr. PC27_Function selection C-9 (**COP9)]

Initial value
00000000h
[Pr. PC27.0_Encoder pulse count polarity selection]
Initial value
0h
Select the polarity of the linear encoder.
0: Encoder pulse increasing direction in the servo motor CCW or positive direction
1: Encoder pulse decreasing direction in the servo motor CCW or positive direction
[Pr. PC27.2_ABZ phase input interface encoder ABZ phase connection assessment
function selection]
Initial value
0h
Select the non-signal detection status for the pulse train signal from the A/B/Z-phase input interface encoder being used as a
linear encoder.
This function is enabled when an A/B/Z-phase input interface encoder is used.
Setting value
0
1
1 SERVO PARAMETER DETAILS
60
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Detection of disconnection
Z-phase-side non-signal
Enabled
Disabled
Ver.
Refer to the relevant detail No.
Ver.
B2
Ver.
Refer to the relevant detail No.
Ver.
B2
Ver.
B2
Alarm status
Linear
[AL. 020.6 Encoder normal communication - Transmission
data error 2] (Z-phase)