At Command - Queue Parameter Value Frame - 0X09 - Digi XTend vB DigiMesh User Manual

Radio frequency (rf) module
Table of Contents

Advertisement

API frames

AT Command - Queue Parameter Value frame - 0x09

Description
This frame allows you to query or set device parameters. In contrast to the AT Command (0x08)
frame, this frame queues new parameter values and does not apply them until you issue either:
The AT Command (0x08) frame (for API type)
n
The AC command
n
When querying parameter values, the 0x09 frame behaves identically to the 0x08 frame. The device
returns register queries immediately and not does not queue them. The response for this command is
also an AT Command Response frame (0x88).
Format
The following table provides the contents of the frame. For details on frame structure, see
specifications.
Frame data
fields
Frame type
Frame ID
AT command
Parameter value 7-n
Example
The following example sends a command to change the baud rate (BD) to 115200 baud, but does not
apply the changes immediately. The device continues to operate at the previous baud rate until you
apply the changes.
Note
In this example, you could send the parameter as a zero-padded 2-byte or 4-byte value.
Frame data fields
Start delimiter
Length
Frame type
XTend vB DigiMesh RF Module User Guide
Offset Description
3
0x09
Identifies the data frame for the host to correlate with a subsequent
4
ACK (0x88). If set to 0, the device does not send a response.
5-6
Command name: two ASCII characters that identify the AT command.
If present, indicates the requested parameter value to set the given
register. If no characters are present, queries the register.

AT Command - Queue Parameter Value frame - 0x09

Offset
0
MSB 1
LSB 2
3
API frame
Example
0x7E
0x00
0x05
0x09
82