Table of Contents

Advertisement

NetAgent
BT UPS Enterprise SNMP Agent
User Manual
Version 6.1
Issue Date March 2019

Advertisement

Table of Contents
loading

Summary of Contents for BT NetAgent Series

  • Page 1 NetAgent BT UPS Enterprise SNMP Agent User Manual Version 6.1 Issue Date March 2019...
  • Page 2 BT UPS Enterprise SNMP Agent Contents Page Introduction Features 4 Applications NetAgent Models NetAgent9 Models NetAgent 9 Mini Outlook NetAgent UPS Installation NetAgent, UPS and Network Connection Install the NetAgent II with UPS and Network Install the NetAgent Mini with UPS and Network...
  • Page 3 BT UPS Enterprise SNMP Agent SNMPView – Windows Based UPS Management System Introduction System Requirements Install SNMPView Using SNMPView SNMPView Buttons Appendix A - Update the firmware of NetAgent UPS Appendix B -3 Ports NetAgent II with SMS Modem Appendix C –SMS Server with SMS Modme...
  • Page 4 BT UPS Enterprise SNMP Agent 1 Introduction 1.1 Features NetAgent is a new generation SNMP (Simple Network Management Protocol) monitoring product. Not only could remote control the UPS and get the current status of it, the NetAgent II –3Ports also could provide other functions, ex. connect to Modem or GSM Modem to make the monitoring possible when there is no permanent connection to Internet and sens SMS notification .
  • Page 5 BT UPS Enterprise SNMP Agent When there is a power abnormal condition happens, the NetAgent could also send the trap information to the system manager to take proper action. 1.2.2 NetAgent Provides Shutdown Utilities When a computer on the network with the NetAgent utility installed, it could locate all the NetAgent on the network.
  • Page 6 BT UPS Enterprise SNMP Agent Fig.2 3 Port NetAgent II Diagram 1.3 NetAgent Models 1.3.1 NetAgent Models NetAgent II Model Package Contents Internal/External 1/3 Ports 1/3 phases CP504 CT504 1Port Internal card NetAgent Utility CD Internal User Manual 1Port External card...
  • Page 7 BT UPS Enterprise SNMP Agent 3 Port Internal card NetAgent Utility CD BP506 User Manual Internal 3. M2506 Cable (for Modem) NetAgent Mini Model Package Contents Internal/External 1/3 Ports 1/3 phases DP520 DT520 1. Internal NetAgent Mini NetAgent Utility CD...
  • Page 8 BT UPS Enterprise SNMP Agent CP504 CP503 BP506 BP505 NetAgent Mini (DP Series) DP520 DP522 DP532 Issued by: BT Page 8 of 103 Version no: 6.1 Date: March 2019...
  • Page 9 BT UPS Enterprise SNMP Agent DP801 DP802 1.3.3 Pictures of NetAgent • NetAgent Utility CD, including: Netility:Configure NetAgent IP address, update firmware ClientMate:Windows, Linux, FreeBSD shutdown utility. SNMPView:Windows platform multiple NetAgent UPS management software. SMS Server: SMS Notification UPS MIB:MIB file for the Network Management System...
  • Page 10 BT UPS Enterprise SNMP Agent o Ports NetAgent (Internal / External): LED Table Yellow Green Status Solid Off Solid Off Solid ON Power ON Flashing Solid ON Solid ON System initial Solid ON Solid Off Solid ON Normal operation Solid ON...
  • Page 11 BT UPS Enterprise SNMP Agent Flashing Flashing Solid ON Writing data to flash memory Green light : Power state Red light : Connection state with UPS Fig.2 NetAgent II Out looking 1.3.5 NetAgent Mini OutLook NetAgent Mini External NetAgent Mini Internal Module...
  • Page 12 BT UPS Enterprise SNMP Agent Package Content Internal/External 1/3Ports 1/3Phase 3 Ports External Agent NetAgent Utility CD User Manual M2501 Cable (for Contact Closure UPS) 3Ports M2502 or M2505 Cable. (for RS232 UPS) BX505 External M2506 Cable (for Modem) 9V DC adapter 1.
  • Page 13 BT UPS Enterprise SNMP Agent CX504 CX503 BX506 BX505 NetAgent 9 Mini (DX Series) DX520 DX801 Issued by: BT Page 13 of 103 Version no: 6.1 Date: March 2019...
  • Page 14 BT UPS Enterprise SNMP Agent 1.4.3 NetAgent 9 Package Contents • NetAgent Utility CD, including: Netility:Configure NetAgent IP address, update firmware ClientMate:Windows, Linux, FreeBSD shutdown utility. SNMPView:Windows platform multiple NetAgent UPS management software. SMS Server: SMS Notification UPS MIB:MIB file for the Network Management System...
  • Page 15 BT UPS Enterprise SNMP Agent 1.4.4 NetAgent 9 Outlook • Port NetAgent (Internal / External) 3 Ports NetAgent (Internal / External) : Issued by: BT Page 15 of 103 Version no: 6.1 Date: March 2019...
  • Page 16 BT UPS Enterprise SNMP Agent LED Table Yellow Green Status Solid Off Solid Off Solid ON Power ON Flashing Solid ON Solid ON System initial Solid ON Solid Off Solid ON Normal operation Solid ON Flashing Solid ON No connection to UPS...
  • Page 17 BT UPS Enterprise SNMP Agent Green Power state On: Normal power Connection state with UPS Flash: no connection with UPS Orange Correspondence state Light flashes when Netagent transmits command to UPS Light signal application of NetAgent 9 Mini - LAN Port LED...
  • Page 18 BT UPS Enterprise SNMP Agent 2 NetAgent UPS Installation Before using the NetAgent, the proper hardware and software configuration is necessary. Hardware installation is to connect the NetAgent and UPS and network. Software configuration includes the IP address. Firmware upgrade. Or using the Browser or Telnet for configuration.
  • Page 19 BT UPS Enterprise SNMP Agent 3 NetAgent, UPS and Network Connection NetAgent II and NetAgent Mini provides External and Internal model for different UPS interface requirement. Please reference the following description for detailed information of UPS and network connection. 3.1 Install the NetAgent II with UPS and Network Fig.5 NetAgent II Installation...
  • Page 20 BT UPS Enterprise SNMP Agent 3.2 Install the NetAgent Mini with UPS and Network NetAgent Mini - External NetAgent Mini -Internal To UPS To LAN DC Adapter To UPS To LAN 3.2.1 For External NetAgent Mini Connect the NetAgent Mini to LAN, using the UTP port.
  • Page 21 BT UPS Enterprise SNMP Agent 4 Using Netility Setup IP Update Firmware 4.1 Install Netility • Insert NetAgent Utility CD to the CD-ROM driver and execute Netility.exe. • After complete installation, there will be a ‘Netility’ group in Windows ’Start’...
  • Page 22 BT UPS Enterprise SNMP Agent Click Launch Device or double click the NetAgent listed in the table to launch it. Enter the Account (Login Name) and Password (Login Password) set earlier to login. If you did not configure one, then just click Apply to login.
  • Page 23 BT UPS Enterprise SNMP Agent Netagent UPS provides HTTP/HTTPS(WEB) and Telnet to reference any related parameter setting for the manager. Concerning with security, the manager could build use openly or any advance port setting methods. Followings are the description: 1. At advanced setting, two functions were set as activated by using port number 80 and 23 for Http and Telnet.
  • Page 24 BT UPS Enterprise SNMP Agent Netility Password - After password setting here, there is no way to give any command to NetAgent by Netility software without user’s password. (NB. If lose this password, Netagent UPS will never be able to complete any upgrade process.)
  • Page 25 BT UPS Enterprise SNMP Agent Fig.11 Netility : Update NetAgent UPS firmware • About - Netility version examined Fig.12 Netility version examined Refresh List - Search Lan’s Netagent UPS manually Netility would search all the available NetAgent from Lan automatically, or the user could search manually by click on “Search NetAgent”...
  • Page 26 BT UPS Enterprise SNMP Agent 5 UPS Web management by NetAgent 5.1 Introduction After finishing NetAgent installation, including hardware installation and IP setting, you are now able to go to NetAgent web site to monitor and control UPS by inputting NetAgent IP address in Browser.
  • Page 27 BT UPS Enterprise SNMP Agent 5.2 NetAgent UPS Web Interface Enter NetAgent UPS Web page,there are 4 main function items in the first Web page: • Information • Configuration • Log Information • Help Enter the main function item, the sub-menu items will be shown on the left side of the page.
  • Page 28 BT UPS Enterprise SNMP Agent Fig.16 NetAgent UPS - 3 ports Fig. 17 NetAgent 9 5.2.1 Information Sub-Menu : • System Status • Basic Information • Current Status • Remote Control Issued by: BT Page 28 of 103 Version no: 6.1...
  • Page 29 BT UPS Enterprise SNMP Agent • Meter/Chart • Modem Status • Environment Sensors-NetFeeler II Note: The options available on this menu depend on the NetAgent model. (e.g. “NetFeeler II” will not be display for one port.) 5.2.1.1 System Status This page is to show NetAgent system information and Network settings. Values shown here are either provided by NetAgent itself or they are user settings from the Configuration pages.
  • Page 30 BT UPS Enterprise SNMP Agent UPS Information Information about UPS Manufacturer/UPS Firmware Version/UPS Model are provided by the UPS. Battery Information Values here are user settings from the Configuration pages. Rating Information Values here are provided by the UPS. Fig.19 Basic Information 5.2.1.3...
  • Page 31 BT UPS Enterprise SNMP Agent Fig.20 Current Status 5.2.1.4 Remote Control This page is to provide remote UPS test functions. Choose the test item, then click on 'Apply' to execute it. (Please refer to the UPS manual for individual UPS Test functions.)
  • Page 32 BT UPS Enterprise SNMP Agent UPS Buzzer On/Off This is to trigger UPS buzzer On. If its ON already, execute such command will set it OFF Fig.21 Remote Control 5.2.1.5 Meter/Chart This page displays temperature, capacity, load, voltage etc. of the UPS by appearing with meters/chart diagram.
  • Page 33 BT UPS Enterprise SNMP Agent Fig 23. NetAgent 9 Meter/Chart Fig.24 NetAgent 9 Meter/Chart 5.2.1.6 Modem Status (For 3 Ports NetAgent II only) Modem Information This section displays the modem information. GSM Modem Operating Status This section displays the operating status between NetAgent and Modem.
  • Page 34 BT UPS Enterprise SNMP Agent Fig.25 Modem Status 5.2.1.7 Environment Sensors-NetFeeler II 3 Ports NetAgent could be connected to NetFeeler II to detect the environmental status. NetFeeler II is to detect Temperature , Humidity and Water. It can receive signals from wireless smoke sensors, gas sensors and security sensors to detect further environmental conditions.
  • Page 35 • Email • • Modem Port • NetFeeler II • NetSwitch Action (Apply on BT Model) WEB/Telnet • • System Time • Language Please set each parameter correctly, so that NetAgent would operates properly. Note: This page’s selection would differ according to the differrent interface of the UPS.
  • Page 36 BT UPS Enterprise SNMP Agent 5.2.3 UPS Configuration This page is to set the UPS configuration. Any wrong settings will cause incorrect display values or disconnection between the UPS and NetAgent. 5.2.3.1 UPS Properties UPS Communication Type This section is to set up the communication interface of the UPS. (eg. Contact Closure/Megatec/Phoenixtec/ Megatec 3 phase etc.) Please refer to the UPS manual to set...
  • Page 37 BT UPS Enterprise SNMP Agent This section is to set the UPS critical loading. (shown as %) NetAgent will send a warning message when the UPS is overloaded. Critical Temperature (C) This section is to set the UPS critical internal temperature. NetAgent will send warning messages when the UPS overheats.
  • Page 38 BT UPS Enterprise SNMP Agent 5.2.4.4 Wake On LAN This section is to wake the PC within the network. (Make sure the PC has such function supported and configure as “Enabled” under BIOS.) Enter the IP address of that PC and system would search its IP accordingly.
  • Page 39 BT UPS Enterprise SNMP Agent This section is to set NetAgent Gateway. Obtain an IP address This section is to choose to set NetAgent IP address manually or via DHCP. The above 4 sections can be set in Netility as well. NetAgent will reboot after any of the above are changed.
  • Page 40 BT UPS Enterprise SNMP Agent Enter the Password you have assigned to your DDNS Account. Use external STUN server to get Public IP to register Choose Yes to ensure that NetAgent uses the WAN / Public IP to update the selected DDNS server.
  • Page 41 BT UPS Enterprise SNMP Agent 5.2.6 Wireless This is to configure Wireless network with USB wireless dongle. This feature only apply to NetAgent 9 model of BX series. (USB wireless dongle is optional) NetAgent 9 BX models supports wireless encryption of Open system; Shared Key; WEP (64 /128 bit) / WPA / WPA2(TKIP/AES) Following is the wireless configuration.
  • Page 42 BT UPS Enterprise SNMP Agent Click on information → System Status, under Wireless Status, it displays the IP address of the wireless network Fig.32 NetAgent 9 Wireles 5.2.7 SNMP This page is to set NetAgent SNMP settings so it can be used by an NMS (Network Management System).
  • Page 43 BT UPS Enterprise SNMP Agent Community This section is to set a Community name for NMS. The community name has to be as the same as the setting in NMS. Permission This section is to set authorities of administrators. Options are Read, Read/Write, and No Access.
  • Page 44 BT UPS Enterprise SNMP Agent 5.2.7.4 Trap Notification Receiver IP Address This section is to set receivers IP address for receiving traps sent by NetAgent. It is valid for up to 8 IP Addresses. Community This section is to set a Community name for NMS. The community name has to be as the same as the setting in NMS.
  • Page 45 BT UPS Enterprise SNMP Agent 5.2.7.5 Device Connected This section is to set the usage power and connection status of other devices which connects to the same UPS as NetAgent uses. 5.2.7.6 SNMP UDP This is to configure the UDP port of the NetAgent and trap receiver. SNMP default port is 161;...
  • Page 46 5.2.8 2.2.6 Email This page is to set Email details for use by NetAgent. NetAgent CP、DP series only support SMTP NetAgent BT、CT、DT series and NetAgent 9 series of BX、CX、DX supports SMTP and SSL SMTP。 5.2.8.1 Email Setting Email Server This section is to set NetAgent Email Server . Note that free email server such...
  • Page 47 BT UPS Enterprise SNMP Agent 5.2.8.3 Recipient’s Email Address (for Daily Report) This section is to set Email Addresses to receive Daily Report email sent by NetAgent when an event occurs. It is valid for up to 4 Email addresses.
  • Page 48 BT UPS Enterprise SNMP Agent 5.2.10 To send SMS by single port of NetAgent. It requires to use remote “SMSAgent” or freeware SMS Server. 5.2.10.1 SMS Settings Send SMS when Event Occurs This section is to select if use local modem or remote service to send SMS. Select local modem when modem connects with 3 Ports NetAgent.
  • Page 49 Communication Type Suitable Condition When NetAgent connects with Megatec’s GSM/GPRS Modem PPP Dial-in When NetAgent connects with dial in modem NetSwitch When NetAgent connects with BT NetAgent 5.2.11.2 SMS Setting SMS Communication Communication Type Suitable Condition GPRS To use with GSM 900/1800 or GPRS 900/1800/1900...
  • Page 50 To send instant SMS, enter recipient’s mobile number and SMS text with configurable of Unicode or Character format 5.2.11.4 NetSwitch (BT series only) When BT NetAgent connects with NetSwitch on RPM, it able to perform action to the specific outlet when following event or alarm triggers. Events 1.
  • Page 51 Fig 40. Modem Port with NetSwitch NetSwitch Status When BT connects with NetAgent, this will appear under Information option. This section allows remote control over the RPM unit and its individual devices. Click on the individual power input icon to either switch on / off the device...
  • Page 52 BT UPS Enterprise SNMP Agent Fig.41 NetSwitch Status NetSwitch Action This is to configure the action on specific event when occur. NetSwitch would executes the action per setting as to turn on or turn off on the assigned outlet Click on New to select event and set action.
  • Page 53 This is to configure the parameter of the radius server. Please refer to the appropriate radius server setting Only for NetAgent BT、CT、DT series and NetAgent 9 series of BX、CX、DX models Enable RADIUS in Web/Telnet login To select between Yes or No...
  • Page 54 BT UPS Enterprise SNMP Agent 5.2.12.4 SSL Certificate Information This is to upload the SSL certificate. When both public key and certificate are uploaded to NetAgent web server, the communication will be encrypted by SSL on the Internet by entering with Http:// on the browser.
  • Page 55 BT UPS Enterprise SNMP Agent Fig.45 NetAgent 9 Radius 5.2.13 System Time This page is to set NetAgent system time. You can provide NetAgent with up to 2 time servers or you can set a time zone. 5.2.13.1 System Time Time Between Automatic Updates This section is to set an interval for time synchronization.
  • Page 56 BT UPS Enterprise SNMP Agent Manual Restart System After 30 Seconds Use this feature to manually restart the system NetAgent restart in about 30 seconds. 5.2.13.4 Backup Time This is to save the event log and data log automatically with the configured hour on external USB flash.
  • Page 57 BT UPS Enterprise SNMP Agent 5.2.14 NetFeeler II (For 3 Ports NetAgent II only) This page is to set Environmental sensors-NetFeeler II’s configurations. 5.2.14.1 NetFeeler II Critical UnderRun This section is to set the lowest critical values for temperature and humidity. NetFeeler II will send a warning message when it detects temperature or humidity values below these settings.
  • Page 58 West Firmware English, German, Portuguese, Spanish, French, Italian, Turkish, Russian NetAgent CT, DT and BT supports the following languages English, Traditional Chinese, Simplified Chinese, Korean, Japanese, Russian, Thai, German, Portuguese, Spanish, French, Italian, Turkish, Russian, Polish NetAgent 9 CX, DX and BX suports the following languages...
  • Page 59 BT UPS Enterprise SNMP Agent Date/Time This is a record of the Date (yyyy/mm/dd ) and Time ( hh:mm:ss ) that the event occurred. Event This is a detailed description of the event. Save This is to save the event log Fig.51 Event Log...
  • Page 60 BT UPS Enterprise SNMP Agent 5.3.2 This page is a SMS Event log. It shows a record of all mobile number, giving the Date/Time of the SMS sent and a detailed description of each. When reach to the limit, it rewrites on the previous logs Fig.52 SMS Log...
  • Page 61 BT UPS Enterprise SNMP Agent Env. Humidity This section shows environmental humidity which detected by NetFeeler II Fig.53 Date Log 5.3.4 Save Data Log This function is to record RS232 UPS’s voltage, frequency, load, capacity, temperature, etc. to save as another file for the other purpose to the manager.
  • Page 62 BT UPS Enterprise SNMP Agent Fig.54 Save Data Log 5.4 Help 5.4.1 Search NetAgent This to display all the found NetAgent within network with its serial number; Mac Address; Hardware/Firmware version and its IP address. Double clicking on the highlighted unit to open the webpage of such device Fig.55 Browse NetAgent...
  • Page 63 BT UPS Enterprise SNMP Agent If Debug mode is set as manually, user may enter its parameter under Send Contents column. Sent Information This column shows the real time sent command Received Information This display the response that NetAgent receives from UPS Fig.56 Serial ports debug...
  • Page 64 BT UPS Enterprise SNMP Agent Reset to factory default This function will reset all settings to its default value. 5.4.4.3 Firmware Update Setting Default FTP server is set as ftp.icv99.com with its username/password. Click on Update Now, NetAgent will connects to the FTP server and upgrade to the latest firmware version accordingly.
  • Page 65 BT UPS Enterprise SNMP Agent 6 Telnet (Remote Configuration) 6.1 Introduction NetAgent supports multiple Network Management systems and LAN protocols. After finishing hardware installation, you are now able to choose any utilities that provided by NetAgent to monitor and control UPS.
  • Page 66 BT UPS Enterprise SNMP Agent • Main screen is as follows: Fig.61 NetAgent Telnet window 6.2.1 Set IP Address. This function allows you to setup IP Address, Gateway Address, Subnet Mask parameters. 6.2.2 Set SNMP MIB System. This function allows you to set the MIB system group parameters.
  • Page 67 BT UPS Enterprise SNMP Agent 6.2.9 Set E-mail. This allows to set e-mail accounts to receive power event notification for emergency management. a. Reset Configuration to Default. Set all values to their default settings. b. Save & Reboot. Save the current configuration data, including any changes you have made, and reboot the Net Agent.
  • Page 68 BT UPS Enterprise SNMP Agent • Main Menu Issued by: BT Page 68 of 103 Version no: 6.1 Date: March 2019...
  • Page 69 BT UPS Enterprise SNMP Agent 7 ClientMate - Windows Shutdown Utility ClientMate is a utility for connecting to NetAgent. This utility is for the Windows platform. When the ClientMate get the power failure signal from the NetAgent. The ClientMate will save the files and shutdown the system gracefully.
  • Page 70 BT UPS Enterprise SNMP Agent 7.2.1 Config When the ClientMate gets the signal from the NetAgent about the AC power failure or battery low signals, the ClientMate will based on the configuration below to initiate the shutdown process. The details of the configuration are here below Fig.63 ClientMate: Configuration...
  • Page 71 BT UPS Enterprise SNMP Agent (S): The UPSilon2000 or RUPS2000 Host SNMP Port and Community Name (For NetAgent only) The community name and SNMP port must be the same as configured on NetAgent. Default SNMP Port is 161 Broadcast Warning Messages (On Server platform only)
  • Page 72 BT UPS Enterprise SNMP Agent Execute the application before system shutdown. Fig.64 ClientMate Configuration 7.2.2 Closed Files User could review all the files closed during previous shutdown process. If the “Auto save application files” function has been turn-on in the “Setting” dialog, the details of the closed application and files could be reviewed here.
  • Page 73 BT UPS Enterprise SNMP Agent Fig.66 ClientMate:About 7.2.4 Event log Press this button could review all the network status and UPS status happened. Shown as below. Fig.67 ClientMate:About 7.2.5 IP address of connection Status ICON Description Connecting with NetAgent UPS at IP 192.168.0.162...
  • Page 74 BT UPS Enterprise SNMP Agent 7.2.6 AC power status Status ICON Description The connected NetAgent UPS AC power is normal The connected NetAgent UPS AC power is failed 7.2.7 Battery Status Status ICON Description The connected NetAgent UPS battery is in normal condition The connected NetAgent UPS is in battery low condition 7.2.8...
  • Page 75 BT UPS Enterprise SNMP Agent 8 SNMPView – Windows Based UPS Management System 8.1 Introduction SNMPView is a software to remotely monitor and control multiple UPS connected to a network. When an event occurs, SNMPView can be programmed to send an email or a pager to inform the designated network manager.
  • Page 76 BT UPS Enterprise SNMP Agent • Click “NetAgent” € “SNMPView” € “SNMPView for Windows” to start using SNMPView. 8.4 Using SNMPView When use SNMP view at the first time, the system will ask for input the user's name and password. Please enter the default value as follows to start the SNMPView.
  • Page 77 BT UPS Enterprise SNMP Agent Shows that the device is a UP Shows that the UPS is Battery Low Shows that the UPS is Disconnect / Off-Line 8.5 SNMPView Buttons When use SNMPView, configuration could be done by all function icons displayed or right click on the mouse to show functions list.
  • Page 78 BT UPS Enterprise SNMP Agent 5.1.10 Quit 5.2.1 Large Icons 5.2 View(S) 5.2.2 Small Icons 5.2.3 Details 5.2.4 Map Background 5.3.1 UPS Settings 5.3 Tools(P) 5.3.2 UPS Monitor 5.3.3 SNMP Management 5.4.1 Event Log 5.4 System(S) 5.4.2 Data Log 5.4.3 SNMP Option 5.5 User(U)
  • Page 79 BT UPS Enterprise SNMP Agent 8.5.1.2 Enumerate This is to edit or display all the group station of NetAgent under network 8.5.1.3 Add UPS Click “Add UPS” to enter the IP address of the UPS manually. Once entered, the UPS will be shown on the main list.
  • Page 80 BT UPS Enterprise SNMP Agent 8.5.1.5 Browse Device Highlight the unit to be browsed and click it to enter NetAgent’s webpage. 8.5.1.6 Export Configuration This is to save the NetAgent UPS’s configuration 8.5.1.7 Import Configuration This is to import the configuration of NetAgent UPS that saved 8.5.1.8...
  • Page 81 BT UPS Enterprise SNMP Agent Open up “SnmpElog.dat”, event log would show as below 8.5.1.9 Open archive Data Log Open up “SnmpDlog.dat”, SNMPView would show the event log of all NetAgent UPS Issued by: BT Page 81 of 103 Version no: 6.1...
  • Page 82 BT UPS Enterprise SNMP Agent Open up “SnmpDlog.dat”, data log would show as below: 8.5.1.10 Quit Exit SNMPView. 8.5.2 View(S) This is to choose the presentation format of NetAgent UPS. 8.5.2.1 Large Icons Large icon view to display IP address and its location...
  • Page 83 BT UPS Enterprise SNMP Agent 8.5.2.2 Small Icons Small icon view to display NetAgent UPS’s IP address, Name, location…etc 8.5.2.3 Details Detailed Information displays NetAgent UPS’s IP address, name, input voltage, output voltage, battery capacity, load, frequency…etc. Issued by: BT Page 83 of 103 Version no: 6.1...
  • Page 84 BT UPS Enterprise SNMP Agent 8.5.2.4 Map Background Import a map image (JPG) by right click on the main screen and move NetAgent UPS icon to its suitable location. 8.5.3 Tools(P) Highlight NetAgent UPS device and configure. 8.5.3.1 Settings General This to configure UPS information, record UPS event, enable trap alarm...etc...
  • Page 85 BT UPS Enterprise SNMP Agent SMS Notification Send SMS when event occurs Trap List Double click on the trap that listed and configure Issued by: BT Page 85 of 103 Version no: 6.1 Date: March 2019...
  • Page 86 BT UPS Enterprise SNMP Agent UPS Loading To configure all the other devices and its load that connects with NetAgent UPS. Double click on the device listed and configure 8.5.3.2 UPS Monitor Highlight NetAgent UPS device and configure. Or right click on the highlighted device and click on monitor device.
  • Page 87 BT UPS Enterprise SNMP Agent Details Display NetAgent UPS’s IP address, location, user, manufacturer and all other detailed information. Issued by: BT Page 87 of 103 Version no: 6.1 Date: March 2019...
  • Page 88 BT UPS Enterprise SNMP Agent Event Log This display event happened with date/time and its description. Control • Turn Off UPS: To shutdown UPS • Reboot UPS: UPS shuts down in 12 seconds, and reboot in 1 minute. • LED: Enable LED flashes. (UPS must supports it) •...
  • Page 89 BT UPS Enterprise SNMP Agent Once choose the function that to perform and click on “Execute” Note: UPS must supports those function to perform it Test Control • UPS Self Test: Execute UPS Self Test • UPS Calibration Test: Execute UPS Calibration Test Turn-Off Parameters •...
  • Page 90 BT UPS Enterprise SNMP Agent 8.5.4 System(S) To view event log, data log and configuration 8.5.4.1 Event Log Display event log, date/time and description of all NetAgent UPS. 8.5.4.2 Data Log Display input voltage, output voltage, frequency, load…etc of all NetAgent UPS.
  • Page 91 BT UPS Enterprise SNMP Agent 8.5.5 User(U) Total of 8 users account can be created to manage and control its NetAgent UPS 8.5.5.1 Change Password To change existing user’s password to login 8.5.5.2 User Management This only for Admin user to add, edit or remote other user’s info 8.5.6...
  • Page 92 BT UPS Enterprise SNMP Agent 8.5.6.2 About Display the current SNMPView version, Copyright information and product service contact. Issued by: BT Page 92 of 103 Version no: 6.1 Date: March 2019...
  • Page 93 BT UPS Enterprise SNMP Agent 9 Appendix A - Update the firmware of NetAgent UPS NetAgent provides the following convenient methods for user to update the latest firmware of the NetAgent 1. Click firmware upgrade under About of NetAgent webpage and it would link to Megatec’s server to download the latest firmware.
  • Page 94 BT UPS Enterprise SNMP Agent - Once the account and password been checked, the server will response with 230 OK to indicate Login succeeded. - If entered wrong account and password, the server will response with 530 Not Logged in to indicate Login failed.
  • Page 95 BT UPS Enterprise SNMP Agent Again, the password here is the one been set at Netility, if did not set anything before, then enter NetAgent’s default value as: Account: admin Neglect password (ftp://admin:@192.168.50.179) 3.2. ftp://192.168.50.179/ , when using this method to enter, the follow error message will be show.
  • Page 96 BT UPS Enterprise SNMP Agent 10 Appendix B -3 Ports NetAgent II with SMS Modem BP506 & SMS MODEM Hardware Installation: A:GSM MODEM。 B:GSM MODEM Adaptor 。 C:NetAgent BP506。 D:GSM MODEM Cable。 E:RS232 to RJ45 Cable。 2: How hardware should be connected...
  • Page 97 BT UPS Enterprise SNMP Agent 4: Once card inserted, Modem would detects if such SIM card has password and the signal with its ISP. If Led flashes every second continuously, there is no signal been received. OR, SIM card has password, invalid password.
  • Page 98 BT UPS Enterprise SNMP Agent 5: Under Modem status of BP506 webpage, it indicates the status of Modem BP506 SMSConfiguration: BP506→Configuration→ • Select Local Modem • • Enter BP506’s username and password(leave none leave blank)。 1. Enter Mobile number。5.Select events to send。6.Click on Apply。...
  • Page 99 BT UPS Enterprise SNMP Agent 11 Appendix C –SMS Server with SMS Modme GPRS MODEM Installation 1. Insert Sim card 2. Connect DC adaptor to GPRS modem as well serial cable provided to PC com port 2.1. 2.2. 2.3. NOTE:Please make sure there is no conflict port with the GPRS modem...
  • Page 100 BT UPS Enterprise SNMP Agent SMS SERVER Software Installation 1. Click on exe for installation 2. Once installed, the icon would appear on the tool bar 3. Right click on the SMS server icon and check modem status Issued by: BT Page 100 of 103 Version no: 6.1...
  • Page 101 BT UPS Enterprise SNMP Agent SMS Server Software Configuration NetAgent sends SMS via modem 1. Click on SMS in the NetAgent Webpage 2. Enter the SMS server’s IP Service Port:NetAgent & SMS Server port that use for local connection Service account:Account authentication for sending SMS (Leave blank if no such setting)。...
  • Page 102 BT UPS Enterprise SNMP Agent Issued by: BT Page 102 of 103 Version no: 6.1 Date: March 2019...
  • Page 103 Offices worldwide © British Telecommunications plc 2017 Registered office: 81 Newgate Street, London EC1A 7AJ Registered in England No: 1800000...

Table of Contents