Bomag BW 213 D-4 Operating Instructions, Maintenance Instructions page 71

Single drum roller
Hide thumbs Also See for BW 213 D-4:
Table of Contents

Advertisement

Checking the refrigerant level
Start the engine.
l
Fig. 97
Switch the air conditioning (Fig. 97) on.
l
Fig. 98
Choose a cooling temperature with the rotary
l
switch for cabin heater (Fig. 98) in the blue
section.
Open the air outlet nozzles.
l
Check, whether the outflowing air is noticeably
l
cooler.
i
Note
The adjusted temperature must be below the actu-
al temperature inside the cabin, so that the com-
pressor will be switched on.
Open the hood.
l
BW 213 D-4
Fig. 99
Check whether the white float (Fig. 99) inside
l
the inspection glass of the drier/collector unit
floats right at the top.
i
Note
The refrigerant level is correct.
Fig. 100
If the white float (Fig. 100) inside the inspec-
l
tion glass of the drier/collector unit floats at the
bottom, inform the service department.
i
Note
The refrigerant level is not correct.
Refrigerant must be filled up, if necessary
l
check the air conditioning system for leaks.
B O M A G