Fig. 7
No. 2 = Instrument cluster
i
Note
With the ignition switch in position I all gauges and
instruments are switched on for 3 seconds.
a red
= flashes if the engine temperature ex-
ceeds 135 °C, the warning buzzer
sounds, the engine is shut down after
2 minutes.
Switch off vibration, run engine with
idle speed or shut down engine if
necessary, clean engine oil cooler
and radiator, if necessary repair en-
gine.
b red
= flashes if engine oil pressure too low,
engine is shut down after 10 sec-
onds. Check engine oil level, repair
the engine if necessary.
c yellow = Engine air filter, lights if air filter car-
tridge is soiled, clean or replace if
necessary.
d yellow = Charge control light, lights if battery is
not being charged.
Check V-belt, if necessary repair the
generator.
e yellow = lights if the hydraulic oil filter is con-
taminated, the engine is shut down
after 2 minutes.
Check hydraulic system, replace hy-
draulic oil filter.
f yellow = The seat occupation monitoring sys-
tem lights when the seat is not occu-
pied. If the machine is travelling the
warning buzzer will sound, engine is
shut down after 4 seconds.
BW 213 D-4
g red
= Parking brake, with lever shifted to
parking brake position, with driver's
seat unoccupied.
h green = Direction indicator, flashes when the
direction indicator switch is actuated.
i yellow = Water separator in fuel pre-cleaner.
Lights when the water proportion in
the transparent section of the fuel fil-
ter reaches the contacts.
j red
= flashes, when the coolant provision
(filling level) is too low, the engine is
shut down after 2 minutes.
k yellow = not used
l red
= Hazard light, flashes when the haz-
ard light is activated
m
= Operating hour meter, counts the op-
erating hours while the engine is run-
ning. All maintenance work must be
performed according to the indicated
operating hours.
n
= Fuel tank filling level
When falling below the lowest filling
level the last green LED will light and
the red LED will additionally come on.
When the fuel tank is empty only the
red LED will flash.
No. 3 = Vents for air conditioning, heating
and ventilation, driver
No. 4 = Vents for air conditioning, heating
and ventilation, footwell
*
Optional equipment