Bomag BW 213 D-4 Operating Instructions, Maintenance Instructions page 70

Single drum roller
Hide thumbs Also See for BW 213 D-4:
Table of Contents

Advertisement

E v e r y 5 0 0 o p e r a t i n g h o u r s
Tighten the V-belt.
Fig. 95
Slightly slacken fastening screws 1, 2 and 3
l
(Fig. 95).
Press the compressor in direction of arrow, un-
l
til the correct V-belt tension is reached.
Retighten all fastening screws.
l
Changing the V-belt
Slightly slacken the fastening screws 1, 2 and
l
3.
Press the compressor against the direction of
l
arrow completely against the engine.
Take the old V-belt off.
l
Fit the new V-belt to the V-belt pulleys.
l
Tension the V-belt as previously described.
l
Caution
!
Check the V-belt tension after a running time of
30 minutes.
7 0
5.23 Service the air conditioning
Cleaning the condenser
Caution
!
A soiled condenser results in a considerable
reduction of air conditioning power.
Under extremely dusty conditions it may be
necessary to clean the condenser several
times per day.
If, during operation of the air conditioning sys-
tem, the warning buzzer sounds switch the air
conditioning off and clean the condenser.
In case of formation of foam have the air con-
ditioning system inspected by the service de-
partment.
Danger
!
Danger of accident!
Do not clean with a hot water jet. Heat will
cause extreme overpressure, which could
cause damage or explosion of the system.
Use access steps and grips to mount and dis-
mount the machine.
Fig. 96
Unscrew the condenser fastening screws (Fig.
l
96) and fold the condenser forward.
Clean the condenser fins on front and back
l
with compressed air or cold water.
*
Optional equipment
B O M A G
*
BW 213 D-4

Advertisement

Table of Contents
loading