‡Operation

(for ME96SSHA-MB)
»Display Change
Press
, the measurement display switches over.
DISPLAY
When the
and
DISPLAY
2 seconds or more, the display will change in reverse order.
Example of changing display (Three phase 4-wire system; display pattern: P01; no additional screens)
DISPLAY
DISPLAY
<Screen 1 of 4>
<Screen 2 of 4>
Upper: Current
Upper: Current
Middle: Power
Middle: Power
Lower: Voltage
Lower: Power factor

Bar Graph Display

»
Items measured can be displayed on the bar graph. By displaying one item by a bar graph and other three items by digital numbers
four elements can be displayed at once.
• Bar graph explanation
The
or
mark indicates that the measurement item is displayed on the bar graph.
• Select bar graph
Press the
or
button to select the measurement items to be displayed on the bar graph.
Three phase 4-wire system
V
(LN)
(Upper)
AVG
(Middle)
(Lower)
»Maximum/Minimum Display Values
Press the
button to change to the maximum and minimum values
MAX/MIN
of the display screen. Press it again to return to the current value display screen.
Reset Maximum/Minimum Values
»
Press the
button for 2s to reset the maximum/minimum values of
RESET
the measurement items displayed. The maximum/minimum values will
become the current values.
Press the
and
RESET
maximum/minimum values. The maximum/minimum values will become the current values.
»Displaying Active energy/Reactive energy/Apparent energy
Active energy (Imported)
Active energy (Exported)*
Reactive energy
(Imported,lag)
Change the unit (M, k, none) or increase the digits in the bottom display for power used/reactive power used/apparent power
used/time-based power used to check the lower/higher-order digits. Push the
between screens.
Power used (receiving): Example of changing 012,345,678,901,234.567Wh
Hold down
simultaneously
Unit: M
Reset Active energy/Reactive energy/Apparent energy
»
Press the
,
SET
RESET
active energy/reactive energy/apparent energy (this operation only works on the current value display screen).
buttons are held down for
DISPLAY
DISPLAY
<Screen 3 of 4>
<Screen 4 of 4>
Upper: Current
Upper: Current
Middle: Power
Middle: No display
Lower: Voltage
Lower: N-phase current
(clockwise)
(anticlockwise)
∑ W
V
(LL)
A
AVG
AVG
∑ PF
∑ var
Hz
buttons simultaneously for 2s to reset all
Apparent energy
Reactive energy
Reactive energy
(Imported,lead)*
(Exported,lag)*
and
for 2s
Bottom digits increased
and
buttons simultaneously for 2s to reset all of the following together:
PHASE
»Changing Phases
Press
, the current phase and the voltage phase switches over.
PHASE
Example of changing phases (Three phase 4-wire system)
PHASE
DISPLAY
Average current
Current phase 1
Power (total)
Power phase 1
Average voltage (interphase)
Voltage phase 1N
PHASE
PHASE
Current phase 3
Current phase 2
Power phase 3
Power phase 2
Voltage phase 31
Voltage phase 23
Example of switching between changing current value
display and maximum/minimum value display screens
Current value display screen
* To display these screens,
it is necessary to change
the power used measurement
settings using set-up menu 3.
Reactive energy
(Exported,lead)*
and
buttons simultaneously for 2s to switch
Unit: None
PHASE
PHASE
Current phase 2
Current phase 3
Power phase 2
Power phase 3
Voltage phase 2N
Voltage phase 3N
PHASE
PHASE
Current phase 1
Average current
Power phase 1
Power (total)
Voltage phase 12
Average voltage
(between lines)
Example of bottom item
Example of power factor
displayed in the bar graph
displayed in the bar graph
MAX/MIN
Maximum/Minimum value
display screen
Unit: k
PHASE
22