Logging Specifications - Mitsubishi Electric Super-S ME96SS Series Manual

Electronic multi-measuring instrument
Table of Contents

Advertisement

Specifications
®
‡MODBUS
TCP Communication Specifications
Item
Interface
Transmission method
Number of stages connected in cascade Max. 4 stages (10BASE-T), max. 2 stages (100BASE-TX) (when repeater hub is used)
Max. distance between nodes
Max. segment length
Connector applicable to external wiring RJ45
10BASE-T
Cable
100BASE-TX
Protocol
Max. number of connections
Support functions
 For more information on data, please refer to the following document.
Electronic Multi-Measuring Instrument ME series MODBUS

‡Logging Specifications

Item
Logging mode
Detailed data
Kinds of logging
data
1-hour data
Detailed data
Number of logging
elements
1-hour data
Detailed data
Internal memory
logging period
1-hour data
SD memory card (2GB) logging period 10 years or more
System log data
Logging data / system log data output
format
Power failure compensation
(
logging ID, logging elements
Set
and detailed data logging
values
interval
Logging data and system log data
Clock operation
Clock accuracy
Output data storage medium
Optional accessory
*1: Use the SD memory card (EMU4-SD2GB) made by Mitsubishi Electric.
Use of any memory card other than our product (EMU4-SD2GB) is not covered by the warranty.
 For more information on data, please refer to the following document.
Logging specifications...LMS-0551
13
1 port (10BASE-T/100BASE-TX)
Base band
200m
100m
Cable meeting IEEE802.3 10BASE-T standard
(Unshielded twisted pair cable (UTP cable), category 3 or higher)
Cable meeting IEEE802.3 100BASE-TX standard
(Shielded twisted pair cable (STP cable), category 5 or higher)
®
MODBUS
TCP (port No.502)
4
Auto-negotiation function (automatic recognition of 10BASE-T/100BASE-TX)
Auto-MDIX function (automatic recognition of straight cable/cross cable)
®
Interface specifications...LMS-0492
Automatic updating by overwriting (not provided with a function to automatically start according to the start time
setting)
Measurement data is stored at the specified "detailed data logging interval" (1 min, 5 min, 10 min, 15 min or
30 min).
Note: The data will be output as a detailed data file.
Note: As the integrated values, not the difference values, but the values displayed on the multi indicating
instrument will be output.
Measurement data is stored at a one-hour interval.
Note: The data will be output as a one-hour data file or a one-day data file.
Note: As the integrated values, not the difference values, but the values displayed on the multi indicating
instrument will be output.
Max. 6 elements
Max. 6 elements
Detailed data logging interval: 1 min for 2 days
Detailed data logging interval: 5 min for 10 days
Detailed data logging interval: 10 min for 20 days
Detailed data logging interval: 15 min for 30 days
Detailed data logging interval: 30 min for 60 days
400 days (about 13 months)
1200 records
CSV format (ASCII code)
Backup by built-in lithium battery
Total power interruption backup time: 5 years (at daily average temperature of 35°C or less)
(The life of the lithium battery is 10 years (at a daily average temperature of 35°C or less).)
The battery cannot be replaced by the customer. Please consider updating the module.
)
Stored in FRAM (non-volatile memory)
Note: The data will not be deleted even if power interruption is caused by battery voltage drop (BAT. LED is on).
Stored in SRAM (volatile memory)
Note: The data will be deleted if power interruption is caused by battery voltage drop (BAT. LED is on).
Note: The clock operation will stop if power interruption is caused by battery voltage drop (BAT. LED is on).
After power restoration, the clock operation will start from 00:00 on Jan. 1, 2016.
1 min / month
SD memory card (SD or SDHC)
SD memory card (EMU4-SD2GB)
Specification
Specification
*1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents