External Dimensions/Installation/Connections
Dimensions
ME96SSHA-MB, ME96SSRA-MB
Terminal screw M3
ME96SSEA-MB
Terminal screw M3

Mounting

1 Dimension of panel

Panel hole dimensions are as shown in the following figure.
It can be attached to a panel with thickness of 1.6 to 4.0mm.
+ 0.5
92
0
3 Attachment
For attachment of the basic device into the panel hole, attach according to the following procedure.
qThe attachment lug is installed in two holes
of the top and bottom of the basic device.
4 Installing Optional Plug-in Module
When installing the optional plug-in module onto the basic device, install according to the following procedure.
qRemove the optional cover.
27
Optional Plug-in Module : ME-4210-SS96, ME-0040C-SS96, ME-0052-SS96
91.6
Optional Plug-in Module : ME-0000BU-SS96
95.8
91.6
Optional Plug-in Module : ME-0000MT-SS96
95.8

2 View Angle

The contrast of the display changes at view angle. Mount it at the position that is
easy to see.
Viewing angle
10°
60°
(side view)
wTighten the screws of the lug,
and fix onto the panel.
Note
wAttach the optional
unit to the main unit.
88.8
81.2
46.8
88.8
81.2
88.8
81.2
(overhead view)
To prevent damage to the panel and screws, do not fasten
screws too tightly.
Recommended torque for these products: 0.3~0.5N·m (approx.
half of standard torque)
Also, please tighten the upper and lower screws at the same time.
Main unit mounting screws: M3
Fit the protruding part of the optional unit into
the slot in the main unit.
25.2
17.1
25.2
17.1
25.2
17.1