3. Setting
8:Special Settings (Setting Operation Time, Phase Display, IEC Mode)
3.12.
Setting Menu
Set the operation time, phase display, IEC mode.
In the operation mode, press
available.
For more details
about each function, refer to the corresponding pages.
Operation time ⇒ page 74
①Operation time
display
DISPLAY
②Target for counting
Operation time
setting
DISPLAY
③Operation time
threshold
DISPLAY
SET
and
simultaneously for 2 seconds or more, and the following operation becomes
Set "on or off" of the Operation time display that integrates
the time while the target for counting is input and display
it as the load Operation time.
oFF
on
(Not displayed)
(Displayed)
Select the target for counting Operation time from
the auxiliary power, current, and voltage.
AUX
(Auxiliary power)
Item
3-phase 4-wire
AUX
AUX
A
A
AVG
(L-N)
V
V
AVG
Set the target for counting Operation time threshold.
When the auxiliary power (AUX) is selected for the Operation time,
this display will be skipped.
(1)When current is set target for counting Operation time.
min
1 to 120%
(Setting step 1%)
*:If "min" is selected, the Operation time will be counting when
display of current is not 0A.
(2)When voltage is set target for counting Operation time.
min
20 to 120%
(Setting step 1%)
*:If "min" is selected, the Operation time will be counting when
display of voltage is not 0V.
A
V
(Current)
(Voltage)
1-phase 2-wire
Others
AUX
AUX
A
A
AVG
V
V
AVG