Determine Location of MCU
PN: 1725-36096-001_J.doc
Each MCU is approximately 2.75" wide, 12.5" high, and 7" deep, and
weighs about five pounds. The unit is designed to be wall mounted
over 3/4" plywood.
Select a location for the MCU with sufficient backboard space and
an available electrical outlet.
Since the front panel is used for cabling and as an operator's
console, mount the unit so the front panel is accessible.
The MCU must be within 250 feet of the PBX for a digital interface
and within 2,200 feet of the Base Stations.
See your telephone system specifications for distance limitations
for analog modules.
Since the front panel is used for cabling and as an operator's
console, mount the units so the front panel is accessible.
If your system has more than one MCU, the units should be
mounted vertically, side by side physically touching the adjacent
unit. Do not stack units on top of one another. Stacked MCUs can
cause overheating and failure.
Polycom recommends an operational temperature range of 0º–
40º C (31º–104º F). Optimal temperature is 20º C (68º F). Humidity
recommendation is 20%– 80% (non-condensing).
Site Preparation
15