Ite Preparation Checklist - Polycom SpectraLink 6000 System Facility Preparation

Hide thumbs Also See for SpectraLink 6000 System:
Table of Contents

Advertisement

SpectraLink 6100 MCU: Facility Preparation: SpectraLink 6000 System
Site Preparation Checklist
12
MCU location prepared. Typically the MCU is installed in the
telephone equipment room. This location must have sufficient
backboard space. See Chapter 2, section Determine Location of MCU
for more information.
The correct number of cross-connect blocks (or equivalent) are
installed and connected to a 25-pair telco wire terminated with an
RJ-21 male connector at the MCU location. See Chapter 3, section
Prepare Demarc Blocks for more information.
A two-pair cable to each Base Station as designated on the
building floor plans. See Chapter 3, section Run Cables to Base
Station Locations for more information.
The Base Station wire is terminated at the appropriate cross-
connect demarc blocks as shown in Chapter 3 sections Prepare
Demarc Blocks and Connect Cables from Base Stations and Phone Lines
to Demarc Blocks.
The Base Station wiring is terminated with RJ-45 crimp-on plugs
at the designated Base Station locations. See Chapter 3, section
Terminate Cables at Base Station Locations for more information.
The analog or digital-phone extensions from the phone system are
terminated at the appropriate cross-connect demarc block and the
block is labeled. See Chapter 3, section Connect Cables from Base
Stations and Phone Lines to Demarc Blocks.
A dedicated dial line is available for the diagnostic modem.
A system administrator is designated for the SpectraLink 6000
System. This person should be present for the installation. The
Polycom field service engineer will provide system training to the
system administrator on the day following the installation.
When this checklist is completed please sign, date, and fax to
Install Coordination at 303-449-7016.
Signature: ____________________________________________________
Date: ________________________________________________________
PN: 1725-36096-001_J.doc