Technical data

8.5 Liner

8.4

Design

Table 8-8
Design
Version
MAG 1100
Material
● Enclosure
MAG 1100 Stainless steel AISI 316L
(1.4404)
● Terminal box
Fibre glass reinforced polyamide
Standard
(not for Ex)
Option
Stainless steel AISI 316 (1.4436)
● Fixing studs
Stainless steel AISI 304 (1.4301),
Number and size to EN
1092-1:2001
● Gaskets
EPDM (max. 150 °C, PN 40
- Standard
(max. 300 °F, 600 psi))
- Option
Graphite (max. 200 °C, PN 40
(max. 390 °F, 600 psi))
PTFE (max. 130 °C, PN 25
(max. 270 °F, 300 psi))
● Pipe
● Stainless steel
connection
● Hastelloy
adapters:
● PVDF
DN 2, 3, 6 and
10 (1/12",
1/8", ¼" and
3/8")
8.5
Liner
Table 8-9
Liner
Version
MAG 1100
Ceramic
DN 2 and 3 (1/12" and 1/8"):
Zirconium oxide (ZrO
DN 6 to 100 (¼" to 4"):
Aluminum oxide Al
PFA
Reinforced PFA (not for Ex)
52
www.eltra-trade.com
MAG 1100 HT
Stainless steel AISI 316L
(1.4404)
Stainless steel AISI 316 (1.4436) Fibre glass reinforced polyamide
Stainless steel AISI 304 (1.4301),
Number and size to EN
1092-1:2001
Graphite (max. 200 °C, PN 40
(max. 390 °F, 600 psi))
MAG 1100 HT
DN 15 to 100 (½" to 4"):
) (ceramic)
Aluminum oxide Al
2
O
2
3
info@eltra-trade.com
MAG 1100 F
Stainless steel AISI 316L
(1.4404)
(not for Ex)
Stainless steel AISI 316 (1.4436)
Stainless steel AISI 304 (1.4301),
Number and size to EN
1092-1:2001
For ceramic:
FKM/FPM with stainless steel
insert (AISI 304/1.4301)
(-20 ... +150 °C (-4 ... +302 °F))
EPDM
(-20 ... +150 °C (-4 ... +302 °F))
For PFA:
EPDM
(-20 to +150 °C (-4 to +302 °F))
NBR
(-20 to +100 °C (-4 to +212 °F))
MAG 1100 F
Aluminum oxide Al
O
2
3
Reinforced PFA (not for Ex)
O
2
3
+421 552 601 099