Electrodes; Cable Entries; Cable Data - Siemens SITRANS MAG 1100 Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS MAG 1100:
Table of Contents

Advertisement

8.6

Electrodes

Table 8-10
Electrodes
Version
Ceramic
PFA
8.7

Cable entries

Table 8-11
Cable entries
Version
8.8

Cable data

Description
www.eltra-trade.com
MAG 1100
DN 10 to 100 (3/8" to 4") :
Platinum with gold /
Titanium brazing alloy
DN 2 to 6 (1/12" to ¼"): Platinium
DN 10 to 15 (3/8" to ½"):
Hastelloy C276
DN 25 to 100 (1" to 4"):
Hastelloy C22
MAG 1100
● Remote installation
2 x M20 or 2 x ½" NPT
● Compact installation
MAG 5000/MAG 6000:
4 x M20 or 4 x ½" NPT
MAG 6000 I: 2 x M25
(for supply/output)
MAG 6000 I Ex de: 2 x
M25 (for supply/output)
Cable for standard electrode or coil
Electrode cable, double shielded
Cable kit with standard coil cable and electrode cable double
shielded (also available as low noise cable for MAG 1100 sensor)
MAG 1100 HT
Platinum with gold /
Titanium brazing alloy
MAG 1100 HT
Remote installation
2 x M20 or 2 x ½" NPT
info@eltra-trade.com
Technical data
8.8 Cable data
MAG 1100 F
Platinum with gold /
Titanium brazing alloy
DN 10 to 15 (3/8" to ½"):
Hastelloy C276
DN 25 to 100 (1" to 4"):
Hastelloy C22
MAG 1100 F
● Remote installation
2 x M20 or 2 x ½" NPT
● Compact installation
MAG 5000/MAG 6000:
4 x M20 or 4 x ½" NPT
MAG 6000 I: 2 x M25
(for supply/output)
MAG 6000 I Ex de: 2 x
M25 (for supply/output)
+421 552 601 099