A-2.3 Temperature And Charger Output; Inverter Ac Fault Current; Optional Equipment And Accessories; Figure A-3, Temperature To Continuous Charger Output Current - Magnum Energy MagnaSine Hybrid MSH3012RV Owner's Manual

Pure sine wave inverter/charger
Table of Contents

Advertisement

Appendix A – Specifi cations
A-2.3
Temperature and Charger Output
The following curve (Figure A-3) is plotted to show the MSH3012RV charger's continuous output
current as the ambient temperature rises.

Figure A-3, Temperature to Continuous Charger Output Current

A-3 Inverter AC Fault Current
The following table is provided in accordance with CSA C22. No. 107.1-2017, Clause 10.4.5.

Table A-1, AC Output Fault Current - Inverter Mode

Test Condition
Output Short Circuit
A-4 Optional Equipment and Accessories
The following Sensata Technologies components are available for use with the MSH3012RV.
Standard Remote Control
The ME-RC remote control panel uses an LCD screen and at-a-glance LEDs display for complete
inverter/charger status. Soft keys provide simple access to menus, and a rotary encoder knob
allows you to scroll through/select a wide range of settings.
Advanced Remote Control
The ME-ARC remote control panel uses an LCD screen and at-a-glance LEDs to provide operating
information and allow advanced features to be confi gured (requires an inverter with advanced
confi gurable features).
Auto Generator Start Controller
The ME-AGS-N Automatic Generator Start controller (Network version) is designed to automatically
start a wide range of generators based on low battery condition or high temperature. Adjustable
settings when using the ME-ARC include starting the generator based on battery voltage, time of
day, battery State of Charge, or high temperature.
Battery Monitor Kit
The ME-BMK Battery Monitor Kit is a single battery bank amp-hour meter that monitors the condition
of the battery, provides information to let you know how much energy you have available, and
lets you plan your electrical usage to ensure the battery is not being over-discharged. Order Part
Number: ME-BMK-N to receive the battery monitor without the 500A/50mv DC shunt.
Page 51
130
120
110
100
90
80
30
35
25
Temperature (°C)
Max Output Fault Current
240.5 Amps Pk-Pk
40
45
50
Peak Duration
1.45 mSec
© 2020 Sensata Technologies
55
60
3-Cycle RMS Value
76.08 Amps