T
Magnum Inverter/Charger (INV 1)
Figure 2-17, RV-C Connections (Two Inverters with Accessories)
Information on the RV-C plug/connector:
•
Plug (4-pin) – PN: 39-01-2040 (Molex 5557 Series)
•
Crimp-on connectors (female) – PN: 39-00-0039 (Molex 5556 Series)
•
Input voltage: 8 VDC – 17 VDC
•
Input amperage: 40mA typical, 60 mA Max @12V
•
Operating Temperature Range: -20 to 60 Deg C
RV-C
Connector
(on inverter)
3
4
3
1
1
2
Figure 2-18, RV-C Connector/Plug Designation
2.9
Final Inspection
1. Verify all cables are secured with wire ties or other non-conductive fasteners to prevent chafi ng
or damage from movement and vibration.
2. Verify strain reliefs or grommets are in place to prevent damage to the wiring where it passes
through walls, bulkheads, or other openings.
3. Verify all AC connections are correct and torqued to a maximum of 16 in lbf (1.8 N-m).
4. Replace the covers on the main electrical/distribution panel.
5. Replace the chassis access cover.
6. Verify the inverter's front panel switch is in the "OFF" position.
© 2020 Sensata Technologies
Network Bus/
Backbone In RV
RV-C
compliant
device
ME-AGS-N
RV-C Plug
(cable end)
4
2
RV-C
compliant
device
Magnum Inverter/Charger (INV 2)
Pin
1
2
3
4
Installation
T
ME-BMK
Designation
CAN_H
CAN_L
PS–
PS+
Page 30