AS-i Speed Monitor

Configuration

8.
Configuration
Parameters are set similar to the AS-i Safety Monitor using the PC interface and
reading back the data per text. Communication between the Speed Monitor and
the PC is over AS-i.
8.1

Parameters

VBA-2E-KE4-ENC-S
Each channel uses the following parameters:
AS-i Address
Channel activated, channel not activated
Detection of Safety Stop active, detection of Safety Stop not active
Maximum allowed safe speed
Detection of rotating direction.
VBA-2E2A-KE4-ENC/SSI-S
There are following parameters for each channel:
AS-i Address
Type of encoder
Encoder parameters
Filter settings
safe coupling of encoder.
The function of the safe AS-i signals and the safety outputs can be freely config-
ured via the ASIMON software.
Information!
For additional information, please refer to the separate documentation for the ASIMON
software.
8.2

Setting parameters using AS-i Master with integrated Safety Monitor

Information!
Setting parameters using AS-i Master with integrated Safety Monitor is only possible
with VBA-2E-KE4-ENC-S .
1.
The Speed Monitor is connected to the AS-i circuit.
2.
The non-safety slave is addressed.
3.
The connected axes are brought to safe speed. If multiple Speed Monitors
are connected, the Projecting button is actuated. The CONF LED flashes.
4.
From the menu select "Speed Monitor." If multiple Speed Monitors are con-
nected, you can select which device (AS-i address of the non-safety slave)
is parameterized.
5.
This menu is displayed