Function Selector Switch (Only With Vba-2E-Ke4-Enc-S); Projecting Button - Pepperl+Fuchs AS-i Manual

Speed monitor
Hide thumbs Also See for AS-i:
Table of Contents

Advertisement

AS-i Speed Monitor
Product Description
5.5.1

Function selector switch (only with VBA-2E-KE4-ENC-S)

Off On
S1 - Off (RUN)
normal operationing state
S1
S2
S1 - On (Clear)
Factory setting mode
S3
S2, S3 (NC)
Reserved
Off On
S1
S2
S3
Information!
Function selection switches S2 and S3 currently have no function. In the future these
will be used for selecting various options (e.g. encoder or resolver).
Mode for factory settings
The function selection switch S1 can be used to reset the device to its default set-
tings.
Disconnect AS-i voltage.
Set the function selection switch S1 to the On position (Clear).
Finally connect AS-i voltage again.
A run light on LEDs ST1, ST2, F1 and F2 appears for 5 s.
During this time push and hold the projecting button as long as the running
light stops flashing.
The device is reset to its factory default settings.
Set the function selection switch S1 to the Off position (Run).
The device is in the normal operating state.
5.5.2

Projecting button

VBA-2E-KE4-ENC-S
The Projecting button can be used to store currently present frequencies. The
stored values can then be loaded via software.
While values are being stored the CONF LED flashes.
The CONF LED goes out again as soon as the stored values have been loaded.
Values stored using the Projecting button are deleted at Power-on.
Information!
The exact sequence of the parameterization is described in Sec. <Configuration>.