Unit version 1.18 of the AI Controller corresponds to Sysmac Studio version 1.25. Therefore, you
can use only the functions that are supported by unit version 1.18 of the AI Controller. You cannot
use functionality that was added for unit version 1.21 or later of the AI Controller.
Using an AI Controller with an Earlier Unit Version
If you use an AI Controller with an earlier version, select the unit version of the used AI Controller or
an earlier unit version in the Select Device Area of the Project Properties Dialog Box on the Sysmac
Studio. The unit version that you selected is the project unit version of the project. You can use only
the functions that are supported by the project unit version.
Example: Unit version of AI Controller: 1.18
Sysmac Studio version: 1.29
Unit version 1.21 of the AI Controller corresponds to Sysmac Studio version 1.29. However, the
used AI Controller is unit version 1.18, so select version 1.18 as the version in the Select Device
Area of the Project Properties Dialog Box.
If you select version 1.18 as the version in the Select Device Area of the Project Properties Dialog
Box, you can use only the functions that are supported by project unit version 1.18. You cannot use
functionality that was added for unit version 1.21 or later of the AI Controller.
Additional Information
Project Unit Version for Projects
• With Sysmac Studio version 1.02 or higher, you can select the unit version in the Select De-
vice Area of the relevant dialog boxes.
• You can select any unit version that is the same as or earlier than the unit version of the AI
Controller. For example, if the unit version of the AI Controller is 1.21, select either 1.18 or
1.21.
• The Sysmac Studio will treat the project unit version as the unit version for the AI Controller.
For example, if the project unit version is 1.18, you can use only the functionality for unit ver-
sion 1.18 on the Sysmac Studio.
• You can transfer a project to the Sysmac Studio if the project unit version is the same as or
earlier than the unit version of the destination AI Controller.
• Refer to theSysmac Studio Version 1 Operation Manual (Cat. No. W504) for details on the
Select Device Area of the relevant dialog boxes.
NX/NY-series Artificial Intelligence Machine Automation Controller User's Manual (W594)