8. IMD configuration

This section describes how to configure the IMD in a specific setup (such as motor, resolver brake and
so on). When the configuration is finished and verified, it can be saved as a configuration file created
for use in installation process during production. See the IMD Manager user manual for detailed
information about how to use the IMD Manager.
Info
If a parameter is not applicable due to another parameter setting, it will be hidden.

8.1 Prerequisites

The following is needed for the configuration:

8.1.1 Hardware

IMD connected with all the HW that is going to be used in the turbine. Some of the HW can be
simulated if necessary:
Motor (with or without resolver)
Brake (if the IMD is to control the brake)
Connections of digital inputs and outputs
Protected (fused) 400 V AC. The connection must have a breaker.
If the IMD variant used doesn't contain 24 V DC power supply, a separate 24 V DC power supply
is needed as well.
Protected (fused) batteries or ultra-caps for safe energy. The connection must have a breaker.
Safety-chain connections, or if safety-chain is not used, SCI inputs must be connected either as
shown in
Figure 31
chain. If RO is used, it is possible to open and close it using the IMD Manager.
A computer for the IMD manager connected to the "Service" connector of the IMD.
Datasheet and specifications for motor, resolver (if used) and brake.
Info
It is possible to configure the IMD without the accessories (motor, resolver, SSI encoder
and so on) and mains. In this case 24 V DC power supply must be connected to X7. Errors
will be present for the missing components, but the parameter configuration can be done.
Some of the described procedures (for example resolver offset calibration) cannot be
performed. The SE charger (option) cannot be configured without mains.

8.1.2 Software

A computer with the IMD Manager and USB driver running. See IMD Manager Installation instructions
for PC requirements and SW installation instructions.
www.deif.com/wind-power
on page
51
or through RO relay in order to be able to reset the IMD safety-
IMD configuration
Page 79 of 243

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imd 122 bImd 122 cImd 135 cImd 122 a

Table of Contents