This section describes the mapping of bits in parameters where single or multiple bits represent
specific setting or state.
Attention
"Not used" or "Reserved" bits must not be changed.

13.2.1 User options (01)

See also general definition of the parameter in the
Table 32
Reg. ID 0x01, CANopen Object ID 2001
Bit
Name
Bit 0
TEMP_MOTOR_PT
Bit 1
ON_TIME_PT
Bit 2
SSI_TYPE
Bit 3
Not used
Bit 4
DIRECT_SAFETY_RUN
Bit 5
SE_TEST_ANYWHERE
Bit 6
AC_RESTART_
SAFETY_RUN
Bit 7
I_MAX_EXTEND
Bit 8..10
Reserved
www.deif.com/wind-power
parameter
list.
Description
Motor temperature sensor:
0: KTY 84/PTC
1: Pt100
PT100 filter:
0: standard low-pass filter
1: extended low-pass filter
Type of SSI encoder:
0: 12+12 (Multi-turn)
1: 12+1 (single-turn)
Device enabled if no limit switch is active at start-up:
0: Drive must be enabled in order to make a safety run
1: No extra command is needed to initiate a safety-run
(disabled if motor temperature < -18°C)
Safe energy test initiation:
0: SE test can only be executed if a limit switch is
activated
1: SE test can be executed with no regards to limit
switch
Safety run when AC mains return after AC mains
missing during safety run:
0: No new safety run
1: A new safety run is automatically initiated when the
AC mains returns while the IMD is in state 12 (Safety-
run pending). The IMD goes to state 12 if the AC
mains is missing during a safety run.
Permissible value of I max peak:
0: I max pk can be maximum 100%
1: I max pk can be maximum 115% (with reduced T-
peak)
Parameter description
Page 197 of 243