Safe Energy Monitoring - Deif IMD 100 Series Integration Manual

Integrated motor drive
Table of Contents

Advertisement

IMD 100 Integration manual 4189360015 Rev. G
Flag
Register
GO
0xE3
LS 1
0xE4
LS 2
0xE5
Logic-1
0xE6
Logic-2
0xE7
RUN
0xE8
I fault
0xE9
I ballast
0xEA

6.3 Safe energy monitoring

The IMD monitors continuously the SE voltage. Using CAN/CANopen or the IMD Manager, it is
possible to read the actual SE voltage. IMD 122 C has an extra input for measurement of the mid-
point voltage. A wrong mid-point voltage, SE voltage or both, is an indication that a battery or ultra-
capacitor module are defective). No warning or configuration are associated with this function, and the
IMD does not take any action or evaluation. Evaluating the value and taking actions is done by
external controller.
If the SE voltage is below SE Vlow parameter value, a "POWERVOLTAGE sources < min" warning is
generated, it is not possible to disconnect mains either from the IMD Manager or CAN/CANopen.
NOTE If no SE source is connected, the measured values of SE+ and SEM are random (0 to DC-link
voltage) due to the protection circuit or the charger. However, the charger will detect it and
report an error.
www.deif.com/wind-power
Description
The same as 0xD8 bit 11 (GO)
The state of limit switch 1 digital input
The state of limit switch 2 digital input
The state of DI 1 (digital input)
The state of DI 2 (digital input)
The state of RUN digital input
If 1: Internal error in the power section (an error will be generated as
well)
Internal state of the
Ballast circuit.
0: Ballast resistor is OFF, 1: Ballast resistor is ON
Functions description
Page 62 of 243