Conair Carousel Plus D Series User Manual page 34

With dc-c touchview technology
Table of Contents

Advertisement

2
TIP: Make the water supply and
discharge / return connections
with flexible hoses at least 24 in.
(61 cm) long. This allows you to
easily remove the aftercooler as-
sembly for cleaning.
IMPORTANT: If an optional flow con-
trol is also being installed with the
aftercooler, the manual shut off
valve should be installed on the
inlet line for the flow control.
3 - 1 4
l I n s t a l l a t i o n
C o n n e c t i n g t h e A f t e r c o o l e r a n d
O p t i o n a l P r e c o o l e r
The aftercooler and/or optional precooler require a source of city, tower, or chiller water
and a discharge or return line. You can use water at temperatures of 45 to 85°F {7 to
29°C}.
aftercooler inlet
aftercooler outlet
IMPORTANT: Turn the water off when the dryer is not in use to prevent condensation.
Recommended Water Flow Rates
Dryer Model
gal./min. {liters/min.}
600
15 {56.8}
800
15 {56.8}
1000
20 {75.7}
1300
25 {94.6}
1600
25 {94.6}
2000
25 {94.6}
2400
25 {94.6}
3200
30 {113.6}
4000
30 {113.6}
5000
30 {113.6}
( D 1 3 0 0 - 5 0 0 0 )
1
Connect the water supply line to
the aftercooler or precooler inlet.
If a manual shut off valve is used,
it should be mounted on the inlet
line. Conair recommends that a
manual shut off valve be used on both
the supply and return lines.
2
Connect the water discharge or
return line to the aftercooler
or precooler outlet.