Problem
Regeneration Blower over-
load - If the regeneration
blower exceeds its full load
amp rating or the overload has
tripped due to a mechanical or
electrical problem the dryer
will shut down. The default
setting for this alarm is pas-
sive but it can be changed to
shutdown.
0
NOTE: This alarm shuts
down only the regeneration
portion of the dryer. The
delivery air blower will
continue to run.
6 - 1 4
l Tr o u b l e s h o o t i n g
S h u t d o w n A l a r m s
If an alarm occurs, a red dialog box is displayed on the dryer's touch screen control. The
dryer will shut down automatically to prevent damage to the equipment or personnel.
The dialog box will indicate whether the alarm is a shut down alarm or a passive alarm.
Possible cause
The regeneration blower current draw
has exceeded the full load amps rating
of the motor.
The regeneration blower has mechani-
cally failed or is unable to rotate freely.
The regeneration blower has failed
electrically.
Loss of phase of power to the motor
starter.
The overload is set incorrectly.
The overload is defective.
Solution
Press alarm acknowledge and allow the
overload to reset then try to restart the
dryer. If the alarm condition occurs
again have a qualified electrician check
the current draw to the motor.
Disconnect and lock out main power.
Check the regeneration blower for me-
chanical failure and free rotation. Re-
place if necessary. Allow the overload
to reset then try to restart the dryer.
Disconnect and lock out main power.
Check the regeneration blower for elec-
trical shorts or open circuits. Replace if
necessary. Allow the overload to reset
then try to restart the dryer.
Check for a blown fuse in the dryer or
main power supply. Allow the overload
to reset then try to restart the dryer.
Disconnect and lock out main power.
Check the overload settings and
confirm that the settings match the full
load amps listed on the blower motor.
Allow the overload to reset then try to
restart the dryer.
Replace the overload.