R e p l a c i n g t h e R e g e n e r a t i o n H e a t e r
( W 6 0 0 - 1 0 0 0 )
( c o n t i n u e d )
8
Compare the markings on the outside of the regeneration heater tube to
ensure the new one has the same voltage and kW ratings as the original heater
tube. This information is on the end nearest the wires.
9
Slide the original insulation over the new heater or, if the insulation was cut
for removal, wrap the cut insulation sleeve around the new heater tube and se-
cure it with duct tape.
10
Make sure the cable end of the heater tube is to the
bottom then secure the new heater tube to the
mounting bracket with a hose clamp.
11
Connect the hoses to the top and bottom of the
heater tube and secure them with hose clamps.
12
Connect the high temperature switch wires to the
quick disconnects near the heater tube.
13
Route the heater power cable into the control cabi-
net and connect the leads to the original locations
on the terminal block. Refer to the wiring diagram
for specific connection information.
14
Replace the side panel(s) of the dryer.
15
Measure the resistance from each leg of the heater
tube to the others and from each leg to ground.
There should be +/- 5% resistance variation between all
3 legs, and high resistance from each leg to ground.
16
Connect the dryer to power and turn it on. Verify
that the regeneration temperature achieves the setpoint.
Tr o u b l e s h o o t i n g l
6 - 3 3