S e t t i n g U p Yo u r D M : T h e B a s i c s - A l a r m
L o c a t i o n ( A d va n c e d )
( c o n t i n u e d )
The DM also automatically sets the Alarm Band.
(Establishes the temperature range through
which the alarm can be set.)
NOTE: Process temperatures below the alarm band are assumed
to be insufficient to dry the material.
The Alarm Setpoint is preset at band midpoint.
(Can be changed by the operator to suit the process)
NOTE: If the sensed temperature falls below the Alarm
Setpoint for a longer period than the Delay Time (default is
five minutes), the alarm will trigger an alarm message on the
control.
NOTE: From a cold start: If, after a preset time period, the
temperature read at the selected alarm RTD does not reach
the Alarm Setpoint, DM triggers "Temperature Not Met"
alarm.
(continued)