C O N N E C T I N G T H E M A I N Po W E R - Conair Carousel Plus D Series User Manual

With dc-c touchview technology
Table of Contents

Advertisement

C o n n e c t i n g t h e M a i n Po w e r

CAUTION: Always disconnect and lock out the main power sources before making electrical
connections. Electrical connections should be made only by qualified personnel.
1
Open the dryer's electrical enclosure. Turn the disconnect dial on the dryer door to the
Off or "O" position. Lock out the main power.
Device for complete lock out information.
open.
2
Insert the main power wire through the knockout in the side of the enclosure. Secure
the wire with an appropriate strain relief.
IMPORTANT: Always refer to the
wiring diagrams that came with your
dryer before making electrical con-
nections.
3
Connect the power wires to the three terminals at the top of the power disconnect holder.
4
Connect the ground wire to the ground lug as shown in the photo.
See Introduction: How to Use the Lockout
Turn the captive screw, and swing the door
OFF
O
0
NOTE: Models D600-5000
configured with process
heat and a Heater Pack at
the hopper will require
conduit from the control
panel to the Heater Pack.
See the Appendix, in this
User Guide for more in-
formation about proper
conduit and cable size for
your application.
0
NOTE: Wiring between
process air heater, Heater
Pack, and dryer where con-
trol for this heater is lo-
cated is not included.
Maximum working distance
is 100 feet {30 meters}.
Consult Conair or a quali-
fied electrician to deter-
mine gauge of wire
required for distance.