7.4 Terminal Parameters
7-12
t0
Jump Code
Range:
Default:
Access
Sets the code to jump directly to a specfic parameter within the group.
t1
Digital Input 1 define (I/O Terminal P1)
t2
Digital Input 2 define (I/O Terminal P2)
t3
Digital Input 3 define (I/O Terminal P3)
t4
Digital Input 4 define (I/O Terminal P4)
t5
Digital Input 5 define (I/O Terminal P5)
t6
Digital Input 6 define (I/O Terminal P6)
t7
Digital Input 7 define (I/O Terminal P7)
t8
Digital Input 8 define (I/O Terminal P8)
Range:
Default:
Access
Selects the function for the digital inputs.
0 - 81
0
Tunable
0 =Forward Run Command
1 = Reverse Run Command
2 = Emergency Stop Trip
3 = Reset when a Fault occurs (RST)
4 = Jog Operation Command (2-wire only)
5 = Preset Speed Input - Bit 1
6 = Preset Speed Input - Bit 2
7 = Preset Speed Input - Bit 3
8 = Preset Speed Ramp - Bit 1
9 = Preset Speed Ramp - Bit 2
10 = Preset Speed Ramp - Bit 3
11 = DC Brake during start
12 = 2nd Motor Select
13 = Reserved
14 = Reserved
15 = Frequency increase (UP) Command
16 = Frequency decrease (DOWN) Command
17 = 3-wire operation
18 = External Trip: A Contact (EtA)
19 = External Trip: B Contact (EtB)
20 = Self-Diagnostic Function
21 = Exchange between PID operation and V/F operation
22 = Exchange between option (RS485) and Drive
23 = Analog Hold
24 = Accel/Decel Disable
25 = Up/Down Save Freq. Initialization
t1=0, t2=1, t3=2, t4=3, t5=4, t6=5, t7=6, t8=7