Parameter Descriptions
2 = User V/F is a custom volts per hertz pattern established using
parameters F31~F38.
Voltage
100%
F38
F36
F34
F32
Start
freq.
F31
User V/F frequency 1
F33
User V/F frequency 2
F35
User V/F frequency 3
F37
User V/F frequency 4
Range:
Default:
Access
See Also:
When F30 = 2, selects the frequency for each point in a custom volts per
hertz pattern.
F32
User V/F voltage 1
F34
User V/F voltage 2
F36
User V/F voltage 3
F38
User V/F voltage 4
Range:
Default:
Access
See Also:
When F30 = 2, selects the voltage for each point in a custom volts per hertz
pattern.
Linear
V/F
F37 Base
F31
F33
F35
freq.
0 - 400 [Hz]
F31=15, F33=30, F35=45, F37=60
Configurable
P34, P35, F31-F38, H40
0-100 [%]
F32=25,F34=5-, F36=75, F38=100
Configurable
P34, P35, F31-F38, H40
Freq.
7-33