H37
Load Inertia Rate
Range:
Default:
Access
See also:
Select range according to the connected inertia in relationship to the motor
inertia.
H39
Carrier Frequency Select
Range:
Default:
Access
This parameter affects the audible sound of the motor, noise emission form
the inverter, inverter temperature, and leakage current. If the set value is
higher, the inverter sound is more quiet, but the noise from the inverter and
leakage current will be increased.
H40
Control Mode Select
Range:
Default:
Access
This parameter selects the control mode for the operation of the drive. See
the following description of control method and the corresponding
parameters for adjustment to each.
0=Load inertia rate is less than 10 times that of motor
inertia
1=Load inertia rate equal to approximately 10 times the
motor inertia.
2=Load inertia rate is more than 10 times that of motor
inertia.
0
Configurable
F8-F11, H40
2-15 [kHz]
2
Tunable
0=Volts/Frequency Control
1=Slip Compensation Control
2=PID Feedback Control
3=Sensorless Vector Control
0
Configurable