Baldor VS1MD User Manual page 61

Table of Contents

Advertisement

7-16
23 = Analog Hold: Locks the analog speed reference at the last value
when the input was closed. Available when P40 = Frequency setting
method is set in the range of 2 ~ 7.
6 H W I U H T 
U H T X H Q F \
3 
2 S H U D W L R Q
F R P P D Q G
24 = Accel/Decel Disable: Disables the acceleration or deceleration ramp
while the digital input is closed, holding the reference at its last value.
U H T 
3 
2 S H U D W L Q J
F R P P D Q G
25 = Up/Down Frequency Save Initialization: When the digital input is
active, the last Up/Down frequency is saved. Useable when digital inputs
are configured as 15 = Frequency Increase (UP) and 16 = Frequency
Decrease (DOWN).
t9
Filtering Time Constant for Multi-function input terminal
Range:
Default:
Access
See Also:
The higher the value is set, the slower the responsiveness of the digital
input becomes.
1 - 15
4
Tunable
t1-t8
VS1MD AC Drive User Manual

Hide quick links: