7-36
F54
Overload Warning Level
Range:
Default:
Access
See Also:
Sets the amount of current to issue an alarm signal at a relay or digital
output terminal (see parameters t32 and t33). The value is set as a
percentage of P32 – Motor Rated Current.
Select an output terminal for this function between MO (Digital Output) and
3A~C (Relay Output). If selecting MO as the output terminal, set t32 = 5
(Overload: OL).
F55
Overload warning time
Range:
Default:
Access
See also:
This parameter issues an alarm signal when the current greater than F54 –
Overload warning level flows to the motor for F55 – Overload warning time.
X U U H Q W
0 X O W L  I X Q F W L R Q
R X W S X W
F56
Overload trip enable
Range:
Default:
Access
See Also:
When set to a 1 = enabled, this parameter turns off the inverter output when
the motor is overloaded. Overload level and time are set in F57 and F58
respectively.
F57
Overload trip level
Range:
Default:
Access
See Also:
This parameter sets the amount of overload current before the drive trips.
The value is a percentage of P32 – Motor rated current.
30-150 [%]
150
Tunable
P32, t32, t33, F55
0-30 [sec]
10
tunable
P32, t32,t33, F54
W  2 Y H U O R D G
Z D U Q L Q J W L P H
W
0 - 1
1
Tunable
F57, F58
30-200 [%]
180
Tunable
P32, F56, F58
W
)  