7-52
H70
Frequency Reference for Accel/Decel
Range:
Default:
Access
See Also:
0 = Based on P36 – Frequency High Limit
1 = Based on Delta Frequency
Set the desired Accel/Decel time sin P41 and P42. If H70 = 0, the
acceleration and deceleration time is the time that it takes to reach
maximum frequency from 0 hertz. If you set H70 to 1 = Delta Frequency,
Accel/Decel time is the time that it takes to reach target frequency from a
constant run frequency (current operating frequency). To scale the time
units for accel/decel set parameter H71.
H70 = 0 (Max Frequency)
H70 = 1 (Delta Frequency)
0 - 1
0
Configurable
P36, P41, P42, H71
Max. freq.
60Hz
Run Freq.
30Hz
Run
command
Accel time
S H U D W L Q J
I U H T 
  + ]
 
S H U D W L Q J
F R P P D Q G
 V H F
Decel time
  + ]
7 L P H
> 6 H F @
 
 V H F