Baldor VS1MD User Manual page 6

Table of Contents

Advertisement

1.1 Change from Main Source to 2nd Source
1.2 Parameters
Errata Sheet for the VS1MD Drive Installation & Operating Manual
VS1MD E
The function of parameters P46 and P47 has been changed. A digital input can now
select between the main control and speed setting selected in parameters P38 and
P40 and the secondary source set in parameters P46 and P47. A digital input
programmed in t1 to t8 must be set to "22" Exchange between second source and
drive.
P46
Drive Start/Stop Source 2
Range:
Default:
Access:
See Also:
This parameter serves as an alternate control mode. It is selectable by
a digital input (t1 to t8) = "22" Exchange between second source and
drive.
P47
Frequency Setting Mode 2
Range:
Default:
Access:
See Also:
This parameter serves as an alternate speed reference mode. It is
selectable by a digital input (t1 to t8) = "22" Exchange between second
source and drive.
NOTE: Parameters P46 and P47 are only viewable when one of the t1 to t8
terminals is set equal to "22".
t1-t8
Digital Input 1 define (I/O Terminal P1) to Digital Input 8 define (I/O
Terminal P8)
Range:
Default:
Access:
See Also:
RRATA
0 to 3 (see table for P38)
0 = Keypad
Configurable
P38, P47, t1 to t8
1 to 7 (See table for P40)
1 = Keypad
Configurable
P40, P47, t1 to t8
0 to 25
t1 = 0, t2 = 1, t3 = 2, t4 = 3, t5 = 4, t6 = 5, t7 = 6, t8 = 7
Configurable
n/a