Graco SaniForce SDU Series Manual
Graco SaniForce SDU Series Manual

Graco SaniForce SDU Series Manual

Drum unloader
Hide thumbs Also See for SaniForce SDU Series:

Advertisement

Quick Links

Operation
SaniForce®
SaniForce® Drum
SaniForce®
For use
use with
with hygienic
hygienic bulk
For
For
use
with
hygienic
select
select
select models
models are
models
are approved
are
approved for
approved
Matrix
Matrix
Matrix on
on page
on
page
page 6 6 6 for
for more
for
more information.
more
Important
Important Safety
Important
Safety Instructions
Safety
Read all warnings and instructions in this and other system manuals.
Save
Save all all all instructions.
Save
instructions.
instructions.
Maximum Working Air Pressure: 100
psi (0.69 MPa, 6.9 bar)
Maximum Working Fluid Pressure: See
Technical Data table.
Drum Unloader
Drum
Unloader (SDU)
Unloader
bulk supply
supply of of of medium
medium to to to high
bulk
supply
medium
for use
for
use in in in explosive
use
explosive atmospheres
explosive
information.
information.
Instructions
Instructions
PROVEN QUALITY. LEADING TECHNOLOGY.
(SDU)
(SDU)
high viscosity
viscosity product.
product. For
high
viscosity
product.
atmospheres or or or hazardous
atmospheres
hazardous locations.
hazardous
3A5402J
For professional
professional use
use only.
only. Only
For
professional
use
only.
locations. See
locations.
See Configuration
See
Configuration
Configuration
EN
Only
Only

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SaniForce SDU Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco SaniForce SDU Series

  • Page 1 Operation 3A5402J SaniForce® SaniForce® SaniForce® Drum Drum Drum Unloader Unloader (SDU) Unloader (SDU) (SDU) For use use with with hygienic hygienic bulk bulk supply supply of of of medium medium to to to high high viscosity viscosity product. product. For For professional professional use use only.
  • Page 2: Table Of Contents

    Contents Contents Contents Related Manuals ..........2 Maintenance ............23 Lubrication........... 23 Warnings ............3 Cleaning the Ram Plate........ 23 Configuration Matrix..........6 Cleaning the Pump Lower ......24 Flushing and Storage ........24 Installation............8 General Information ........8 Electro-pneumatic Control Panel Display Choosing a Location for the SDU ....
  • Page 3: Warnings

    Warnings Warnings Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
  • Page 4 Warnings WARNING MOVING MOVING PARTS MOVING PARTS HAZARD PARTS HAZARD HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Pressure Relief Pressure...
  • Page 5 Warnings WARNING EQUIPMENT EQUIPMENT MISUSE EQUIPMENT MISUSE HAZARD MISUSE HAZARD HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
  • Page 6: Configuration Matrix

    Configuration Matrix Configuration Matrix Matrix Configuration Configuration Matrix Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your system. SDU A01AAA1AA0C21 A01AAA1AA0C21 A01AAA1AA0C21 Sample Configuration Configuration Number: Number: Sample Sample Configuration...
  • Page 7 Configuration Matrix Seal Seal Seal Material Material Material Controls Controls Controls Accessories Accessories Accessories‡ Wash Wash Bin Wash Certification Certification Certification A A A Polychloro- 1 1 1 Exposed pneumatic, None 0 0 0 None EN 10204 type prene SST inflatable B B B EPDM 2 2 2...
  • Page 8: Installation

    Before unpacking, examine packing materials for guide for selecting and installing system components. signs of damage. If damaged, take pictures of the damage and contact Graco for directions on how to Reference letters in the text, for example (A), refer to proceed.
  • Page 9 Installation Fig. Fig. 1: 1: 1: Typical installation Fig. System System Components System Components Components Required Required Required Accessories/Components Accessories/Components Not Accessories/Components Not Supplied Supplied Supplied Air cylinders Outlet Line Pressure Relief Valve rated for the expected fluid working pressure Air motor of the pump Displacement pump...
  • Page 10: Control Panel (Exposed)

    Installation Control Panel Panel (Exposed) (Exposed) Control Control Panel (Exposed) When supplied with a continuous supply of air, the control panel can control the SDU functions for manual unloading of drums. NOTE: An SDU that uses a static seal will not have NOTE: NOTE: inflatable seal components on the control panel.
  • Page 11: Control Panel (Enclosed Pneumatic)

    Installation Control Panel Panel (Enclosed (Enclosed Pneumatic) Pneumatic) Control Control Panel (Enclosed Pneumatic) When supplied with a continuous supply of air, the control panel can control the SDU functions for manual unloading of drums. Seal control switch Controls when air is applied to the seal. Air motor control switch Turns air on and off to the air motor.
  • Page 12: Control Panel (Electro-Pneumatic)

    SDU functions for automatic, manual, or batch unloading of drums. This panel is UL508A certified and requires using only Listed or Recognized components. Replacing parts with genuine Graco parts is important to maintain this certification. See the parts manual for replacement part numbers. Touch screen display Operator interface for control of the SDU.
  • Page 13: Air Line Accessories

    Installation Air Line Line Accessories Accessories Line Accessories SDU: Attach the ground cables as shown. Attach • SDU: SDU: the clamp end of the grounding wire to a true earth ground. See Fig. Fig. 1 1 1 . Fig. Outlet Line Line Pressure Pressure Relief Relief Valve...
  • Page 14: Ac Power

    Installation AC Power Power Power 3. Connect equipment to 100 – 240 VAC, single phase, 50/60 Hz, 15 A service with 14 AWG stranded copper wire. Attach to L1 and L2 on power switch as shown. Torque to 8 in-lbs (0.9 N•m).
  • Page 15: Manual Ram Lock

    Installation Manual Ram Ram Lock Lock Manual Manual Lock If the ram plate is detached from the pump lower, the inflatable seal can be installed entirely from the top of the ram plate. If a ram plate inflatable seal is currently installed, follow the procedure in Remove a Ram Plate Inflatable Seal, page 1.
  • Page 16: Remove A Ram Plate Inflatable Seal

    Installation Remove a a a Ram Ram Plate Plate Inflatable Inflatable Seal Seal Remove Remove Plate Inflatable Seal 5. At the rear of the ram plate, pull the inflation tube through the access hole in the recessed groove and the seal gasket (211). This equipment stays pressurized until pressure is relieved manually.
  • Page 17: Adjust Drum Stops

    Installation Adjust Drum Drum Stops Stops Adjust Adjust Drum Stops 6. Lower the ram assembly partially into the drum and inflate the ram plate seal (if applicable). 7. Rotate each drum stop to contact the drum and tighten the drum stop bolts. 8.
  • Page 18: Operation

    Operation Operation Operation Operation Pressure Relief Relief Procedure Procedure Pressure Pressure Relief Procedure 2. For For enclosed enclosed pneumatic enclosed pneumatic control: pneumatic control: control: a. Turn all regulators to zero pressure. Follow the Pressure Relief Procedure b. Open a pressure relief valve on the outlet whenever you see this symbol.
  • Page 19: Start And Adjust The Ram

    Operation Start and and Adjust Adjust the the Ram Start Start Adjust Enclosed pneumatic pneumatic control control panel: panel: 2. Enclosed Enclosed pneumatic control panel: a. Open the air supply to the control panel. b. While observing the position of the ram assembly in relation to surrounding obstacles, operate the ram button to the up position to raise the ram assembly to its...
  • Page 20: Start And Adjust The Pump

    Operation Start and and Adjust Adjust the the Pump Pump Start Start Adjust Pump For Enclosed Enclosed Pneumatic Pneumatic Control Control Panel: Panel: 2. For Enclosed Pneumatic Control Panel: a. Connect pump outlet fittings and hose (not supplied). NOTE: Be sure all components are NOTE: NOTE: adequately sized and pressure rated to meet...
  • Page 21 Operation For Electro-pneumatic Electro-pneumatic Control Control Panel: Panel: 3. For Electro-pneumatic Control Panel: a. Connect pump outlet fittings and hose (not supplied). NOTE: Be sure all components are NOTE: NOTE: adequately sized and pressure rated to meet the system’s requirements. b.
  • Page 22: Change The Drum

    Operation Change the the Drum Drum Change Change Drum 4. Inspect the ram plate and, if necessary, remove any remaining material or material build-up. a. Perform pump pressure relief. See Pressure Relief Procedure, page b. Use a tool to remove material build-up. 5.
  • Page 23: Maintenance

    Maintenance Maintenance Maintenance Maintenance Lubrication Lubrication Lubrication 5. Remove the clamp at the large flange connection where the ram plate attaches to the pump lower and remove the ram plate mounting clamps The pump is lubricated at the factory. It is designed where the ram plate attaches to the ram plate to require no further lubrication for the life of the support rods.
  • Page 24: Cleaning The Pump Lower

    Maintenance Cleaning the the Pump Pump Lower Lower Cleaning Cleaning Pump Lower 7. Raise the ram assembly to lift the air motor off of the pump lower. Stop raising the ram when the air motor clears the pump lower. 8. Slide the ram plate and pump lower out from under the air motor.
  • Page 25: Electro-Pneumatic Control Panel Display Screens

    Electro-pneumatic Control Panel Display Screens Electro - - - pneumatic pneumatic Control Control Panel Panel Display Display Screens Screens Electro Electro pneumatic Control Panel Display Screens When the system is powered up, the Automatic run screen is displayed. The first time the unloader system is powered up, it will be necessary to perform system setup.
  • Page 26 Electro-pneumatic Control Panel Display Screens Specialty key key definitions definitions Specialty Specialty definitions Description Description Description Exit Exit Exit Exit the keyboard or keypad. If the entry has not been saved, any displayed entry shown in the top field of the keyboard or keypad is lost. Backspace Backspace Backspace...
  • Page 27: Startup Screen

    Electro-pneumatic Control Panel Display Screens Startup Screen Screen Startup Startup Screen When the power ON/OFF switch is turned ON, the display shows the startup screen while the system prepares the system for operation. 3A5402J...
  • Page 28: Automatic Screen

    Electro-pneumatic Control Panel Display Screens Automatic Screen Screen Automatic Automatic Screen Feedback enabled Feedback disabled NOTES: NOTES: NOTES: rim of the drum when the start button is released, ram movement ceases. • To prime a full drum for automatic operation, press •...
  • Page 29 Electro-pneumatic Control Panel Display Screens Icon / / / Field Field Description Icon Icon Field Description Description AUTO AUTO SEQUENCE AUTO SEQUENCE SEQUENCE Current Current Recipe Current Recipe Recipe Name of the recipe selected for unloading this drum. Click in this field to display the recipe selection screen.
  • Page 30 Electro-pneumatic Control Panel Display Screens Remote Remote Remote Operation Operation Operation 1. Press the Start button on the screen of your SDU to manually begin the automatic or batch sequence. Let the automatic sequence run until the plate is detected inside the container and the pump primes.
  • Page 31: Manual Screen

    Electro-pneumatic Control Panel Display Screens Manual Screen Screen Manual Manual Screen NOTES: NOTES: NOTES: • These buttons are disabled while the automatic sequence is operating. • Locked recipes disable editing for the pressure boxes on this screen. Icon/Field Description Icon/Field Icon/Field Description Description...
  • Page 32 Electro-pneumatic Control Panel Display Screens Icon/Field Description Icon/Field Icon/Field Description Description Seal Seal Control Seal Control Control Seal Seal Seal Inflate Inflate Inflate Press to inflate the ram plate seal. Stop Stop Stop seal seal seal action action action Stop inflating or deflating the seal. To resume, press the desired seal action button, inflate or deflate.
  • Page 33: Recipe Screens

    Electro-pneumatic Control Panel Display Screens Recipe Screens Screens Recipe Recipe Screens NOTES: NOTES: NOTES: • Recipes may use feedback from external devices Recipes define preset settings for unloader operation to determine when a specific measure of product when unloading defined products. If the SDU will be has been evacuated, so the system settings must operated manually, it is not necessary to define all be completed before any recipes are defined.
  • Page 34 Electro-pneumatic Control Panel Display Screens Material Material Material Recipe Recipe Screen Recipe Screen Screen Icon/Field Description Icon/Field Icon/Field Description Description Recipe Recipe Recipe # # # A numeric list of all available Material Recipes can be exported to a USB device and recipes.
  • Page 35 Electro-pneumatic Control Panel Display Screens Material Material Material Recipe Recipe Recipe Edit Edit Screen Edit Screen Screen When creating a new recipe from scratch, default pressure settings are shown. These pressures are good starting points, but most pressure settings will have to be varied to obtain optimal performance for the specific application.
  • Page 36 Electro-pneumatic Control Panel Display Screens Icon/Field Description Icon/Field Icon/Field Description Description Default Default Batch Default Batch Size Batch Size Size Select a value that is indicative of the normal size of a batch of the product being evacuated. The value can be larger than the contents of the container. In this case, one or more container changes may be required to complete the batch.
  • Page 37 Electro-pneumatic Control Panel Display Screens Material Material Material Recipe Recipe Recipe Timers Timers Timers Screen Screen Screen Icon/Field Description Icon/Field Icon/Field Description Description Press to complete the fields of this recipe with the values assigned to another recipe. The copied values will overwrite any defined values in this recipe. After copying, individual fields can be modified to differentiate this recipe from the one copied.
  • Page 38 Electro-pneumatic Control Panel Display Screens Container Container Container Recipe Recipe Recipe Screen Screen Screen Icon/Field Description Icon/Field Icon/Field Description Description Recipe Recipe Recipe # # # A numeric list of all available Container Recipes can be exported to a recipes. A maximum of 20 (0–19) USB device and viewed or edited on a PC, recipes can be defined.
  • Page 39 Electro-pneumatic Control Panel Display Screens Container Container Container Recipe Recipe Edit Recipe Edit Screen Edit Screen Screen An empty drum is required for defining the container recipe. Icon/Field Icon/Field Icon/Field Description Description Description Recipe Name Name Recipe Recipe Name User-defined alphanumeric field, 19 characters maximum. Lock Lock Lock...
  • Page 40 Electro-pneumatic Control Panel Display Screens Icon/Field Description Icon/Field Icon/Field Description Description Ram Jog Press and hold to lower the ram assembly. Releasing the button will stop lowering the ram. Ram Down Down Down Momentarily press to lower the ram to the lowest position. The ram will continue lowering until the ram has reached the bottom of its travel, unless manually stopped.
  • Page 41: Event Log

    Electro-pneumatic Control Panel Display Screens Event Log Event Event Icon/Field Description Icon/Field Icon/Field Description Description Move up the list. Momentarily Events are Alarms, Deviations, Advisories, and press to move up one entry. Press Records detected by the system. They are logged and hold to continuously move up to assist in troubleshooting the system.
  • Page 42 Electro-pneumatic Control Panel Display Screens ELECTRIC SHOCK SHOCK HAZARD HAZARD ELECTRIC ELECTRIC SHOCK HAZARD To reduce the risk of electric shock when accessing the electrical enclosure while power is present: • All electrical work must be done by a qualified electrician.
  • Page 43 Description Code Code Cause Cause Alarm Network Initialization CA0R An error occurred while Restart the system. Contact Graco Error initializing the system for network Support if the problem persists. communication Alarm Network Interlock EB0R The network interlock is tripped Ensure proper output from the remote...
  • Page 44 Electro-pneumatic Control Panel Display Screens Error Error Error Event Event Type Event Type Type Event Event Event Description Description Description Code Code Code Cause Cause Cause Deviation USB data format WSU2 The data in the file targeted by a Verify data is formatted correctly. No error USB import contains incorrectly commas or new lines should be inserted...
  • Page 45: Job Log

    Electro-pneumatic Control Panel Display Screens Job Log Icon/Field Description Icon/Field Icon/Field Description Description Move up the list. Momentarily The Job Log screen displays a historical log of press to move up one entry. Press jobs completed by the system. Pressing the Job and hold to continuously move up Complete button on the Automatic or Manual run the list until releasing the icon or...
  • Page 46 Electro-pneumatic Control Panel Display Screens A Job Log contains the following information: • Job Number • Job Name • Amount Dispensed • Target Amount for batching • Recipe Number used for the job • Name of recipe used for the job •...
  • Page 47: System Configuration Screen

    Electro-pneumatic Control Panel Display Screens System Configuration Configuration Screen Screen System System Configuration Screen The system configuration screen defines the SDU parameters. The system settings can be exported to a USB device and viewed or edited on a PC, then imported back into the system. See Import and Export with USB, page Icon/Field Description...
  • Page 48 Electro-pneumatic Control Panel Display Screens Icon/Field Description Icon/Field Icon/Field Description Description Lock Lock Lock If a password has been set, press the Lock button to immediately lock all settings from being edited. Enter the password to unlock the settings. The system will automatically lock after two minutes if a password is set and the user leaves the settings menu without pressing Lock.
  • Page 49: Feedback Control Screen

    Electro-pneumatic Control Panel Display Screens Feedback Control Control Screen Screen Feedback Feedback Control Screen To reduce the risk of injury due to electric shock, remove power to the control panel before entering the control panel to make connections for measurement devices. Selecting pulse feedback Selecting scale feedback Icon/Field...
  • Page 50 Electro-pneumatic Control Panel Display Screens Icon/Field Description Icon/Field Icon/Field Description Description Aux 1 1 1 Input Input Input CM8281–11 Input Voltage Asserted: >16 VDC. Not Asserted: <5 VDC Select input type: • None: Not monitored. • Start/Stop: See Remote Operation, page •...
  • Page 51 Electro-pneumatic Control Panel Display Screens Setting Setting Setting K K K - - - Factor Factor Factor Setting Setting Scale Setting Scale Feedback Scale Feedback Feedback In order for a batching cycle to accurately measure In order for a batching cycle to accurately measure product, the K-Factor must be appropriately set and product, the 4 mA Mass and 20 mA Mass settings for the system outlet fluid lines fully loaded.
  • Page 52: Network

    The Network page is used to configure the SDU for network communication. Currently, the system is only configured to communicate through Ethernet/IP (EIP) protocol to a remote programmable logic controller (PLC). Contact Graco Customer Support for information regarding network communication protocols. Icon/Field Icon/Field Icon/Field...
  • Page 53: Ethernet/Ip

    Remote named in the Variable Interface List. 7. Right-click on the Main Task and import the Contact Graco Customer Support to obtain a CopyEthIP program. Once the CopyEthIP configuration file with the .L5K file extension needed program is done importing, the configuration for this procedure.
  • Page 54 Electro-pneumatic Control Panel Display Screens Outputs from from the the Allen Allen- - - Bradley Bradley Controller Controller Outputs Outputs from Allen Bradley Controller Variable Variable Name Variable Name Name Data Data Data Type Type Type Possible Possible Possible Notes Notes Notes Values...
  • Page 55 Electro-pneumatic Control Panel Display Screens Outputs from from the the Allen Allen- - - Bradley Bradley Controller Controller Outputs Outputs from Allen Bradley Controller Variable Variable Name Variable Name Name Data Data Data Type Type Type Possible Possible Possible Notes Notes Notes Values...
  • Page 56 Electro-pneumatic Control Panel Display Screens Inputs to to to the the Allen Allen- - - Bradley Bradley Controller Controller Inputs Inputs Allen Bradley Controller Variable Variable Name Variable Name Name Data Data Data Type Type Type Possible Possible Possible Notes Notes Notes Values...
  • Page 57 Electro-pneumatic Control Panel Display Screens Inputs to to to the the Allen Allen- - - Bradley Bradley Controller Controller Inputs Inputs Allen Bradley Controller Variable Variable Name Variable Name Name Data Data Data Type Type Type Possible Possible Possible Notes Notes Notes Values...
  • Page 58 Electro-pneumatic Control Panel Display Screens SDU Event Event Event Table Table Table Event Event Event Event Event Event Identification Identification Identification Event Log, page 41 for detailed event Number Number Number descriptions. 0,12 Pump Pressure Sensor Error NOTE: The Event Identification Numbers NOTE: NOTE: 0,13...
  • Page 59: About

    Electro-pneumatic Control Panel Display Screens About About About The about screen displays the SDU software information. Icon/Field Icon/Field Icon/Field Description Description Description Removes all user-defined data. This includes locked recipes and passwords, system configuration data, pressure settings, etc. 3A5402J...
  • Page 60: I/O Status Screen

    Electro-pneumatic Control Panel Display Screens I/O Status Status Screen Screen Status Screen Icon / / / Field Field Active Conditions Conditions Icon Icon Field Active Active Conditions Digital Digital Digital Outputs Outputs Outputs Available settings: (blue) Asserted (yellow) Not Asserted Pump fast Pump slow, pump fast Ram up...
  • Page 61: Import And Export With Usb

    Import and Export with USB Import and and Export Export with with USB Import Import Export with Settings Parameters Parameters Settings Settings Parameters When modifying some elements for import, the Settings file requires use of numerical values to represent desired values. The allowable values for To reduce the risk of injury due to electric shock, all fields are detailed in the following table: remove power to the control panel before entering...
  • Page 62 Import and Export with USB Parameter Value Value Meaning Meaning Parameter Value Value Meaning Meaning Parameter Parameter Value Value Value Value Meaning Parameter Parameter Value Value Value Value Meaning Name Name Name Name Name Name Timezone (UTC -05:00) Bogotá, Timezone (UTC +01:00) Brussels, Lima, Quito Copenhagen, Madrid,...
  • Page 63 Import and Export with USB Parameter Value Value Meaning Meaning Parameter Value Value Meaning Meaning Parameter Parameter Value Value Value Value Meaning Parameter Parameter Value Value Value Value Meaning Name Name Name Name Name Name Timezone (UTC +05:30) Chennai, Timezone (UTC +10:00) Canberra, Calcutta, Bombay, New Melbourne, Sydney...
  • Page 64 Import and Export with USB Parameter Value Value Meaning Meaning Parameter Value Value Meaning Meaning Parameter Parameter Value Value Value Value Meaning Parameter Parameter Value Value Value Value Meaning Name Name Name Name Name Name Mass Pounds AUX1/2 None Units Input Kilograms Pump Start/Stop...
  • Page 65: Dimensions

    Dimensions Dimensions Dimensions Dimensions In. (cm) In. (cm) In. (cm) In. (cm) In. (cm) In. (cm) In (cm) In. (cm) 116 (295) 76.2 (194) 21.0 (53.3) 25.0 (63.5) 44.0 (112) 48.0 (127) 27.5 (700) 57.5 (146) 3A5402J...
  • Page 66: Schematic (Exposed Control)

    Schematic (exposed control) Schematic (exposed (exposed control) control) Schematic Schematic (exposed control) 3A5402J...
  • Page 67: Schematic (Enclosed Control)

    Schematic (enclosed control) Schematic (enclosed (enclosed control) control) Schematic Schematic (enclosed control) 3A5402J...
  • Page 68: Schematic (Electo-Pneumatic Control)

    LINE+ 108CP 24 VDC CIRCUIT PROTECTOR 2.0 AMP 1090 24 VDC LOAD+ I/O P OWER LINE 125 1061 1060 GRACO HMI 4PPC70.07 0M-20F001 RDY/F OPS 1 OPS 2 OPS 3 OPS 4 OPS 5 POW ERLINK OP2 OP1 1060 1060...
  • Page 69 Schematic (electo-pneumatic control) BASE- X20BM11 TERMINAL BLOCK- X20TB12 MODULE- X20DS438A 1520 BLACK 1530 BLACK 1540 LASER SENSOR BROWN 1550 SHOP AIR PRESSURE BROWN NOT USED 1560 WHITE BLUE 1570 BLUE 1580 BLACK 1600 SEAL AIR PRESSURE BROWN 1620 BLUE 3A5402J...
  • Page 70 Schematic (electo-pneumatic control) FROM LINE FROM LINE FROM LINE 1061 1060 1061 BASE- X20BM11 BASE- X20BM11 TERMINAL BLOCK- X20TB12 TERMINAL BLOCK- X20TB12 MODULE- X20DO8322 MODULE- X20AO2622 2020 BLACK-2 BLACK-1 1061 WHITE 2270 PUMP FAST SOLENO ID VALVE 1060 BROWN 1060 BROWN 1060 BLACK-2 BLACK-1...
  • Page 71 Schematic (electo-pneumatic control) FROM LINE 1060 1061 BASE- X20BM11 TERMINAL BLOCK- X20TB12 MODULE- X20CM8281 24 VDC OPTIONAL 3.3 mA DIGITAL INPUT 1 24 VDC OPTIONAL 3.3 mA DIGITAL INPUT 2 OPTIONAL 24 VDC 3.3 mA PULSE COUNTER INPUT OPTIONAL 24 VDC 500 mA DIGITAL OUTPUT 1...
  • Page 72 Schematic (electo-pneumatic control) RV2 (SOME MODELS) PRESSURE RELIEF VALVE 85/100/1 30 P SI PUMP 1/2" TUBE 1/2" TUBE PUMP 2 (A) FREE FLOW 3/8" TUBE PUMP CIRCUIT EXHAUST RAM DOWN UP SPEED (CONNECT TUBING TO 3/8" TUBE CYLINDER TOP) FREE FLOW RAM UP 3/8"...
  • Page 73: Kits And Accessories

    Kits and Accessories Kits and and Accessories Accessories Kits Kits Accessories Caster Kit Kit (Accessory (Accessory code code AB) Stainless Steel Steel Piston Piston Rods Rods Caster Caster (Accessory code Stainless Stainless Steel Piston Rods (Accessory code code AE) (Accessory (Accessory code Kit Part...
  • Page 74 Notes Notes Notes Notes 3A5402J...
  • Page 75: Technical Data

    Technical Data Technical Data Data Technical Technical Data Metric Metric Metric Maximum fluid working pressure 5:1 pump 410 psi 2.9 MPa, 28.7 bar 6:1 pump 650 psi 4.5 MPa, 44.8 bar 12:1 pump 1200 psi 8.3 MPa, 83 bar 1:1 diaphragm pumps 120 psi 0.8 MPa, 8 bar Maximum system air inlet pressure...
  • Page 76 Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts.

This manual is also suitable for:

Saniforce sdu a01aaa1aa0c21

Table of Contents