Electro-pneumatic Control Panel Display Screens
Icon/Field
Icon/Field
Icon/Field
Aux 1 1 1 Input
Aux
Aux
Input
Input
Aux 2 2 2 Input
Aux
Aux
Input
Input
Aux1 Output
Aux1
Aux1
Output
Output
Aux2
Aux2 Output
Aux2
Output
Output
Job
Job Measurement
Job
Measurement
Measurement
Delay
Delay
Delay
Current Scale
Scale Value
Value
Current
Current
Scale
Value
* See
Setting K-Factor, page 51
** See
Setting Scale Feedback, page 51
50
Description
Description
Description
CM8281–11 Input Voltage Asserted: >16 VDC. Not Asserted: <5 VDC
Select input type:
• None: Not monitored.
• Start/Stop: See
Remote Operation, page
• Ready Interlock: The system will Alarm if Not Asserted.
• Job Complete: The system will complete and log a job if Asserted, provided there has
been some amount of material dispensed.
CM8281–21 Input Voltage Asserted: >16 VDC. Not Asserted: <5 VDC
Select input type:
• None: Not monitored.
• Start/Stop: See
Remote Operation, page
• Ready Interlock: The system will Alarm if Not Asserted.
• Job Complete: The system will complete and log a job if Asserted, provided there has
been some amount of material dispensed.
CM8281–13 Output Voltage Asserted: 24 VDC. Not Asserted: 0 VDC
Select output type:
• None: Not monitored.
• System OK: Asserted while no Alarms are active.
• Pump Run: Asserted while the pumps are running.
• Sequence Complete: Asserted after an Automatic or Batching sequence has
completed.
• Container Low: Asserted when the system is below the "Container Low" point during
operation.
• Container Empty: Asserted when the system has emptied the container during
operation.
CM8281–23 Output Voltage Asserted: 24 VDC. Not Asserted: 0 VDC
Select output type:
• None: Not monitored.
• System OK: Asserted while no Alarms are active.
• Pump Run: Asserted while the pumps are running.
• Sequence Complete: Asserted after an Automatic or Batching sequence has
completed.
• Container Low: Asserted when the system is below the "Container Low" point during
operation.
• Container Empty: Asserted when the system has emptied the container during
operation.
Delay after a batch is completed, during which the amount pumped is still recorded.
Default is 2 seconds, but may be set up to 5 seconds.
Displays the current read value from the scale.
for more information.
for more information.
30.
30.
3A5402J