Graco SaniForce SDU Series Manual page 55

Drum unloader
Hide thumbs Also See for SaniForce SDU Series:
Table of Contents

Advertisement

Outputs from
from the
the Allen
Allen- - - Bradley
Outputs
Outputs
from
the
Allen
Variable Name
Variable
Variable
Name
Name
AB2BR_rec_primeTime_s
AB2BR_rec_emptyTime_s
AB2BR_rec_sealDeflateTime_s
AB2BR_rec_airAssistTime_s
AB2BR_rec_batchAmount-
Mass_lbs
AB2BR_rec_batchAmountVol-
ume_gal
AB2BR_batchEnabled
AB2BR_networkOverwriteBitfield
3A5402J
Bradley Controller
Controller
Bradley
Controller
Data
Data
Data Type
Type
Type
INT
INT
INT
INT
REAL
REAL
BOOL
DINT
Electro-pneumatic Control Panel Display Screens
Possible
Possible
Possible
Notes
Notes
Notes
Values
Values
Values
INT
Corresponds to bit 10 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
INT
Corresponds to bit 11 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
INT
Corresponds to bit 12 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
INT
Corresponds to bit 13 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
REAL
Corresponds to bit 14 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this value.
Units in pounds.
REAL
Corresponds to bit 15 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this value.
Units in gallons.
TRUE,
Corresponds to bit 16 in the
FALSE
AB2BR_networkOverwriteBitfield
variable. This switches between an
"Auto" sequence and a "Batch" sequence.
Bitfield
This variable is used as a bitfield, where
every denoted output variable has a
corresponding bit. If the remote PLC
intends the SDU to read the value in
from the Ethernet/IP network interface
and make it active in the system, the
corresponding bit for that variable must
be set to TRUE in this bitfield. When a bit
is set to TRUE, any value changes from
the SDU's touchscreen (including loading
a new recipe) will be overwritten by the
network value, unless "Override Remote"
is checked on the SDU Network screen.
When a bit is FALSE, the SDU system
ignores the network value.
55