Graco SaniForce SDU Series Manual page 56

Drum unloader
Hide thumbs Also See for SaniForce SDU Series:
Table of Contents

Advertisement

Electro-pneumatic Control Panel Display Screens
Inputs to to to the
the Allen
Allen- - - Bradley
Bradley Controller
Inputs
Inputs
the
Allen
Bradley
Variable Name
Variable
Variable
Name
Name
BR2AB_systemState
BR2AB_containerLow
BR2AB_containerEmpty
BR2AB_sealInflated
BR2AB_systemLoaded
BR2AB_batchSequenceComplete
BR2AB_autoSequenceComplete
BR2AB_currentJobNumber
BR2AB_ramPosition_in
BR2AB_jobAmountMass_lbs
BR2AB_jobAmountVolume_gal
BR2AB_scaleReading_lbs
BR2AB_evnt_eventTimestamp
BR2AB_evnt_eventGroup
BR2AB_evnt_eventIndex
BR2AB_evnt_acknowledge
56
Controller
Controller
Data
Data Type
Data
Type
Type
Possible
Possible
Possible
Values
Values
Values
DINT
0 (Sys Busy),
1 (Standby),
2 (Manual
Run), 3 (Auto
Run)
BOOL
TRUE,
FALSE
BOOL
TRUE,
FALSE
BOOL
TRUE,
FALSE
BOOL
TRUE,
FALSE
BOOL
TRUE,
FALSE
BOOL
TRUE,
FALSE
DINT
DINT
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
DINT
DINT
SINT
0 (Alarm), 1
(Deviation), 2
(Advisory)
SINT
SINT
BOOL
TRUE,
FALSE
Notes
Notes
Notes
N/A
N/A
N/A
N/A
N/A
This will only be set if batch target
has been achieved. If the batching
sequence ends by emptying the container,
the "BR2AB_autoSequenceComplete"
variable will be set instead.
This will be set when an Auto sequence
completes, or a Batch sequence empties
a container before reaching the target
batch amount.
N/A
Identifies the distance from the laser
position sensor to the top beam or plate of
the system. Units are inches.
Amount of material pumped in the current
job if a "Mass" type feedback is selected in
system settings. Otherwise, this variable
has a value of -1. Units in pounds.
Amount of material pumped in the current
job if a "Volume" type feedback is selected
in system settings. Otherwise, this
variable has a value of -1. Units in gallons.
Identifies the current value of a scale if a
scale is connected and configured in the
system. Units in pounds.
Timestamp in Unix time.
Has a value of 255 if no events need
acknowledgment. See Event Table.
Has a value of 255 if no events need
acknowledgment. See Event Table.
N/A
3A5402J

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saniforce sdu a01aaa1aa0c21

Table of Contents