Electro-pneumatic Control Panel Display Screens
Icon/Field
Icon/Field
Icon/Field
Default Batch
Default
Default
Batch Size
Batch
Size
Size
Pump Slow
Pump
Pump
Slow Pressure
Slow
Pressure
Pressure
Pump
Pump Fast
Pump
Fast Pressure
Fast
Pressure
Pressure
Air
Air Assist
Air
Assist Pressure
Assist
Pressure
Pressure
Seal Pressure
Seal
Seal
Pressure
Pressure
Ram
Ram Up
Ram
Up Pressure
Up
Pressure
Pressure
Ram Down
Down Pressure
Pressure
Ram
Ram
Down
Pressure
Ram
Ram Jog
Ram
Jog
Jog Pressure
Pressure
Pressure
Seal Partial
Partial Pressure
Pressure
Seal
Seal
Partial
Pressure
36
Description
Description
Description
Select a value that is indicative of the normal size of a batch of the product being
evacuated. The value can be larger than the contents of the container. In this
case, one or more container changes may be required to complete the batch.
Select the air pressure to be applied to the pump when running in Pump Slow
Speed. Slow Speed runs automatically when loading a new container of material
to prime the pump, and at the very end of an empty container.
Select the air pressure to be applied to the pump when running in Pump Fast
Speed. Fast Speed is run to evacuate the bulk of the material from the container.
Select the air pressure to be applied under the ram plate to aid in unsticking the
ram plate from the material or the bottom of an empty drum.
Select the air pressure to be applied to the seal while inside the container. Always
choose the lowest pressure that achieves the desired result. Too much pressure
reduces the life of the seal and creates excessive frictional force opposing
movement of the ram. Too little force may cause material to leak past the seal.
Select the air pressure to lift the ram ram plate out of the container. Choose the
lowest pressure that raises the ram without lifting the container.
Select the air pressure to push the ram down against the product during
evacuation. Always use the lowest pressure that achieves the desired result. Too
much down pressure will cause material leakage around the inflatable seal.
Select the air pressure to be applied to the ram when jogging downward.
Select the air pressure to be applied to the inflatable seal when the ram plate is
approaching an overfull container. Choose the lowest pressure that achieves the
desired result. Setting Seal Partial Pressure too high can cause inflatable seal
damage during entry into the container.
Save the current values displayed. If this screen is exited without saving, any
changes made to the screen are lost.
Return to the recipe list screen. If this screen is exited without saving, any changes
made to the screen are lost.