Graco SaniForce SDU Series Manual page 21

Drum unloader
Hide thumbs Also See for SaniForce SDU Series:
Table of Contents

Advertisement

For Electro-pneumatic
Electro-pneumatic Control
3. For
For
Electro-pneumatic
a. Connect pump outlet fittings and hose (not
supplied).
NOTE: Be sure all components are
NOTE:
NOTE:
adequately sized and pressure rated to meet
the system's requirements.
b. Be sure the pump is set to pause. Set the
ram down air pressure to 10 psi (0.06 MPa,
0.6 bar).
c. Touch ram jog icon and lower the ram until it
just contacts the product.
d. If the ram plate is inside the drum, inflate the
seal.
NOTE:
NOTE:
NOTE: To prevent damage to the seal, use
the lowest seal pressure that still allows the
seal to contact the inside surfaces of the
drum.
e. Start the pump at the slow (turtle) speed
setting until the pump is primed. If necessary,
adjust the pump pressure.
f.
Press the Ram Down icon.
g. Using the pressure settings for the various
functions, fine-tune the pressures as needed.
NOTE: Increase air pressure to the ram if the
NOTE:
NOTE:
pump does not prime properly with heavier
fluids. Decrease air pressure if material is
forced out around the inflatable seal.
3A5402J
Control Panel:
Panel:
Control
Panel:
Operation
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saniforce sdu a01aaa1aa0c21

Table of Contents