Material
Material Recipe
Material
Recipe
Recipe Edit
Edit Screen
Edit
When creating a new recipe from scratch, default
pressure settings are shown. These pressures are
good starting points, but most pressure settings will
have to be varied to obtain optimal performance for
the specific application.
The viscosity of the product being pumped will
require a different mix of pressure settings. If differing
viscosities of the same product are pumped, a recipe
with a defined viscosity can be copied and used as
a template to define a new recipe for the additional
viscosity. This creates a new recipe without needing
to enter all new values. Only the values that must
change need to be entered.
Icon/Field
Icon/Field
Icon/Field
Recipe
Recipe Name
Recipe
Name
Name
Lock
Lock
Lock
Auto Raise
Raise
Auto
Auto
Raise
Container
Container Recipe
Container
Recipe
Recipe
3A5402J
Screen
Screen
Description
Description
Description
Press to complete the fields of this recipe with the values assigned to another
recipe. The copied values will overwrite any defined values in this recipe. After
copying, individual fields can be modified to differentiate this recipe from the one
copied.
NOTE:
NOTE:
NOTE: Copying a locked recipe will also copy the password and save the new
recipe as a locked recipe.
User-defined alphanumeric field, 19 characters maximum.
When locked, the password defined on the System Settings page must be entered
to edit the selected recipe. A locked recipe cannot have pressure settings changed
on the Manual screen.
recipe not locked
recipe locked
When checked, an automatic sequence will attempt to lift the ram plate out of the
container and raise the ram to the top of its travel. If not checked, the ram plate
will remain at the location where it is when an automatic sequence completes.
If using batching and the drum is empty before the batch has completed, the
ram plate will auto raise so that another drum can be placed and the run button
pressed to resume the batch unload.
Auto Raise off
Auto Raise on
Select from the list of user-defined container recipes.
Electro-pneumatic Control Panel Display Screens