Replacing The Solenoid Valves Block Complete With Filter - Orved n Series Operating And Service Manual

Machine for heat sealing trays in modified atmosphere
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

10.11 REPLACING THE SOLENOID VALVES BLOCk COMPLETE WITH FILTER

WARNING: This operation must be carried out by a specialist technician.
The solenoid unit layout visible inside the images may vary according to the machine manufacturing year.
1) Make sure the machine is switched off and the plug is removed
from the power socket.
2) Remove the rear panel, by unscrewing the 10 rear fixing screws
using a No. 3 T male hex wrench. Attention! the 2 screws
on the upper edge of the panel can only be accessed with
the sealing head open.
3) Detach the spiralled tube from the pump connection side
and the tank connection side
4) Unscrew the two screws fixing the block
wrench, on the lower side of the intermediate stainless steel
insertion plate.
5) Detach the Rilsan tube Ø 9 mm
Q
nection
, unscrewing the hoseconnector union ring nut
on the left side on the inside using a No. 14 hex wrench.
6) Remove the six Rilsan tubes Ø 9 mm
quick-release couplings (these are identified by their green collar) by marking
them and noting down the position using a marking pen.
7) Disconnect the two black electric cables
U
of the electronic board; then disconnect the terminal from the board (see
image below).
S
N
O
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
N
, by slackening the hose clamps.
O
using a No.10 hex
P
from the gas cylinder con-
S
(4 white + 1 black + 1 red) from the
T
to the left on the connection terminal
ROUTINE MAINTENANCE
L
M
R
T
L
P
Q
R
M
U
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vgp25nVgp60n

Table of Contents