安装遥感器(无线 - Wine Guardian WG15 Installation, Operation And Maintenance Manual

Through-the-wall wine cellar cooling systems
Table of Contents

Advertisement

安装遥感器(无线)
图 1
图 2
图 3
图 4
图 5
63
1. Disconnect the controller wire from the side of Wine Guardian unit and save
for future use.
1. 断开酒卫装置侧面的控制器电线,以备后续使用。
2. Plan on mounting the remote sensor on a solid surface away from doors, corners,
air outlets, drafts or heat generating equipment. Do not mount the remote sensor
directly on an outside wall, wall adjacent to a boiler room, or other hot area as this
runs the risk of influencing its temperature readings. The recommended height is
four to five feet above the finished floor.
2. 请计划将遥感器安装在远离门、角、出风口、通风或发热设备的固体表
面上。请勿将遥感器直接安装在外墙、邻近锅炉房的墙壁或其他高温区
域内,因为这样可能影响其温度读数。建议高度为竣工地面以上 4 至 5
英尺。
3. Remove the sensor face plate (Fig. 1). Mark the mounting points at the
desired location within the wine cellar (Fig. 2).
3. 卸下传感器面板(图 1) 。在酒窖内所需位置标记安装点(图 2) 。
4. Drill two one-eighth inch holes and insert anchors within the mounting surface.
Anchors may not be required if securing to a wall stud or racking system. Insert
screws to secure the sensor to the wall to ensure it mounts easily onto the two
screws and slides down onto the slotted openings freely.
4. 在安装面上钻两个八分之一英寸的孔并插入锚。如果固定在墙柱或支架
系统上,可能不需要锚。插入螺钉,将传感器固定到墙上,以确保其可
以很容易安装到两个螺钉上,并可顺利滑入开槽开口。
5. Input the three AA batteries. (Fig. 3)
(only applicable with wireless installations)
5. 装入三节 AA 电池。 (图 3)
(仅适用于无线安装)
6. Pair the sensor with the unit
(See Page 45 for Pairing Instructions)
6. 将传感器与装置配对
(见 59 页的配对说明)
NOTE: Once Paired the Remote Interface's readings will be
included into the system's temperature and humidity
averages.
注意:配对完成后,远程接口控制器读数将纳入系统的温度与湿度平均值。
7. Mount the Remote Sensor on the wall (Fig. 4)
7. 在墙上安装遥感器(图 4)
8. Reattach the sensor's faceplate (Fig. 5)
8. 重新固定传感器面板(图 5)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wg25

Table of Contents