Condensing Unit; Floor Mounting - Wine Guardian DS025 Quick Start Installation Manual

Split wine cellar cooling system

Advertisement

Fan Coil
A.
Two (2) comm ports
B.
24V control connect to

condensing unit

H.
Refrigerant piping
to condensing unit
C.
Remote Interface
controller w/50'
Condensing Unit
J.
Refrigerant Line
Connections
K.
Refrigerant Sight
Glass
L.
Compressor
P.
Lift handles
D.
Supply duct collar
(standard)
E.
Multi-panel
design
F.
Humidifier control
connection
G.
Condensate drain
I.
Power cord
M.
High Pressure
Switch
N.
Condenser
Coil
O.
Outdoor Cover
30
1.
Unpackage
A.
Remove unit from box. Check for any signs of concealed
damage, and that all optional equipment has been provid-
ed. Contact Air Innovations immediately if components
are missing or/if unit has been damaged in shipping.
B.
Shipment includes:
- One (1) fan-coil unit
- One (1) condensing unit
- One (1) remote interface controller with 50' control cable
- One (1) 7' clear plastic drain hose
2. Installing the Fan Coil
Wine Guardian split system fan coil units should be in-
stalled indoors located near the wine room. Provide a
three-foot clearance around the unit for installation and
future maintenance. The fan coil unit can be located ei-
ther above, or below the condensing unit in height. Keep
any height difference to a maximum of 15' (4.57meters).
Floor Mount

Floor Mounting

Mount the Wine Guardian fan coil on a plywood sur-
face at least 12 inches above the floor to keep it
away from water. Allow adequate space for the rout-
ing and pitch of the external drain.
Wall Mounting
Provide adequate support on both ends of the unit
to accommodate the weight of the system. Construct
Wall Mount
a structurally sound level platform, supported by
angle brackets fastened to the wall.
Ceiling Mounting
Construct a structurally sound, level platform to
place the unit on when hanging it from the ceiling
joists. The system is NOT designed to be suspended
from the top of the unit; it must be supported from
the bottom.
Ceiling Mount
3.
Installing Thermostat (Wired)
A.
Unit is supplied with 50 feet (15 meters) of cable with
RJ-9 type connection along with the Remote User
Interface Controller.
B.
Locate the Remote User Interface within the room
midpoint on a wall in an area with good airflow and
away from any windows or heat sources.
C. Disconnect the wire from the back of the controller
and route the cable to the desired mounting location
within the room.
D. Provide a 3/4" (19 mm) diameter hole within the wall
or racking structure to provide clearance for routing
of the RJ-9 connection at the back of the controller.
3