除霜切出温度
Defrost
cut-out
temperature
除霜检查间隔
Defrost
check
interval
46
设置 11
按下"设置"按钮进入设置 11。
按"向上"或"向下"箭头按钮以调整到所需的设
定点。该设置可由 35 华氏度调节至 50 华氏
度。出厂默认值为 40 华氏度。
注意:该设定点须比设置 10 高出 1°F/°C。
注意:如果选择了°C,然后切换回°F,则默认切
出温度将变为 41°F。
Setting 11
Press "Settings" button to advance to Setting 11.
Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint. This setting is
adjustable from 35°F to 50°F. Factory default is
40°F.
Note: This setpoint must be 1°F/°C higher than
setting 10.
Note: If °C is selected and then switched back to °F
the default cut-out will change to 41°F.
设置 12
按下"设置"按钮进入设置 12。
按"向上"或"向下"箭头按钮以调整到所需的设
定点。该设置可从 0(零)处的 30 分钟、1
处的 1 小时调整,然后在 1 小时内增加到 12
处的最大值 12 小时。
Setting 12
Press "Settings" button to advance to Setting 12.
Press the "Up" or "Down" arrow buttons to adjust
to the desired setpoint. This setting is adjustable
from 30 min at 0 (zero), 1 hour at 1, and then in 1
hour increments up to a maximum of 12 hours at
12.