Figure 2-5, Mms1012-G Model Dimensions - Magnum Energy MMS Series Owner's Manual

Table of Contents

Advertisement

Mounting holes x4
[¼" (0.25") diameter]
3
~ 6 " (6.71")
4
1
~ 7 " (7.51")
2
7
~ 8 " (8.41")
16

Figure 2-5, MMS1012-G Model Dimensions

If installing in a recreational vehicle, do not attempt to use the
vehicle's metal frame in place of the negative connection or DC
ground. The inverter requires a reliable negative and ground
return path directly to the battery.
DC wires and cables should be tied together with wire ties or
electrical tape approximately every 6 inches (15.2 cm). This
helps improve the surge capability and reduces the effects of
inductance, which improves the inverter waveform and reduces
wear on the inverter's fi lter capacitors.
Use only copper wires with a minimum temperature rating of
75°C (167°F).
To ensure maximum performance from the inverter, minimize
all connections from the battery bank to the inverter
Exception: the DC overcurrent disconnect in the positive line.
© 2017 Sensata Technologies
10"
5
16 "
~
8
(16.59")
Installation
5
~ 4 "
8
(4.625")
~ 5"
1
~ 5 "
8
(5.125")
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mms1012Mms1012-g

Table of Contents