Installation

2.0
Installation
You can install individual PV modules in varying combinations of
module quantity, orientation, type, and power rate. Refer to Figure
2 for the MicroGT 500's dimensions.
The MicroGT 500 inverters connect with the split-phase grid, and
operate with most 60 and 72-cell PV modules. The microinverter
auto-senses grid voltage and sets voltage parameters automatically
upon initial power up. For more technical information, please see
the Specifi cations section in this manual.
MODEL NUMBER
MicroGT 500
Maximum MicroGT 500 units per branch:
Maximum parallel combination = x7/branch for a 20A breaker

The MicroGT 500's Independent DC Inputs

Each MicroGT 500 inverter has two independent DC inputs, each
with independent MPPT control and data monitoring.
72.3" (183.6 cm)
Male

Figure 2, MicroGT 500 Dimensions

A PV system using MicroGT 500 inverters is simple to install (Figure
3). Each MicroGT 500 easily mounts on the PV racking, directly
beneath the PV module(s). Low voltage DC wires connect from the
PV module directly to the MicroGT 500, eliminating the risk of high
DC voltage. Installation MUST comply with local regulations/rules.
WARNING: Perform all electrical installations in accordance
with local electrical codes. Installation of this equipment
includes the risk of electric shock. Qualifi ed professionals
should install and/or replace MicroGT 500 inverters.
WARNING: Once the system is connected to the electrical
grid, do not touch any live parts in the system, including
the PV array.
2
AC GRID
PV MODULE
60Hz/240V
60, 72 Cell
88.5" (225 cm)
8.7" (22.1 cm)
LED
© 2016 Sensata Technologies
MODULE CONNECTOR
MC4 Type or Customize
7.5" (19.1 cm)
Female
6.5" (16.5 cm)