8. Even though the light bulb is on, the inverter is currently disabled (off). Press and release the
ON/OFF switch on the inverter to enable (turn-on) the inverter.
9. Disconnect the incoming AC power to the inverter. Verify the light bulb remains on and is
now powered by the inverter.
If the inverter passes all the previous steps, the inverter is ready for use. If the inverter fails any
of the steps, refer to the Troubleshooting section.
A C O u tp u t
120 V ac
( ± 5% )
N eu tral to G ro u n d
< 0.5 V ac
N eu tral to G ro u n d
< 0.5 V ac
A C O u tp u t
120 V ac
( ± 5% )

Figure 2-23, AC Voltage Checks (ME2000 model)

N eu tral to G ro u n d
< 0.5 V ac
A C O u tp u t
A C O u tp u t
120 V ac
120 V ac
(± 5% )
(± 5% )

Figure 2-24, AC Voltage Checks (ME2000-15B/-20B models)

© 2010 Magnum Energy, Inc.
A C T e rm in a l B lo c k

Figure 2-22, AC Voltage Checks

A C W irin g C o m p a rtm e n t
BLAC K
W H IT E
GR EEN
W H IT E W/BLAC K
BLU E
A C W irin g C o m p a rtm e n t
B LA C K
W H IT E
G R E E N
W H IT E w/B LA C K
B LU E
O R A N G E