2 Installation
Installation Instructions
ACT365-VCUs are for indoor installation only and must be installed as permanently connected equipment.
Each ACT365-VCU supports up to four IP cameras.
Mounting
Mount the ACT365-VCU to a solid surface using the supplied screws. The unit should be installed in a
ventilated area that allows for easy access after installation.
2.1 ACT365-VCU Connections
The ACT365-VCU requires an external 12V DC power supply connected to the +12V and 0V terminals on
the ACT365-VCU.
A
Hard Disk / SSD
2.1.1 Ferrite bead installation for the ACT365-VCU
After you install the ACT365-VCU, Vanderbilt recommend that you place the provided ferrite bead (a noise-
suppression device) around the Ethernet cable near the RJ45 connector to attain a desired level of
electromagnetic compatibility (EMC). The ferrite bead is provided along with a screw kit in a clear ziplock
bag inside the unit enclosure.
© Vanderbilt 2019
B
RJ45 Ethernet
9
A-100528-b
20.05.2019