ACT365-VCU / ACT365-VCU2A / ACT365-VCUPoE – Installation and Operating Instructions
Adding the ferrite bead to the Ethernet cable
1. Place the ferrite bead around the un-crimped Ethernet cable.
The ferrite bead should be positioned inside the enclosure, close to the RJ45 connector of the
ACT365-VCU unit, as shown below.
2. Once the ferrite bead is in place, crimp the Ethernet cable at the terminating end.

2.1.2 Power supply

The ACT365-VCU requires an external 12V DC or 24V DC power supply. The supply should be connected
to the +12/24V DC and 0V/GND connections.

2.2 ACT365-VCU2A

This unit is only suitable for installation as permanently connected equipment.
The PSU is not suitable for external installation.
l
Equipment must be earthed.
l
Before installation, ensure that external disconnect device is OFF. The PSU should be installed via a 3A
fused spur according to all relevant safety regulations applicable to the application.
© Vanderbilt 2019
10
Installation
A-100528-b
20.05.2019